Troubleshooting 8-13
Error Messages on Virtual LCD
NEC EXPRESSSCOPE Engine 2 (Remote Management Controller) on your server board allows
you to monitor the server status on the WEB browser-based screen of the client PC via network.
The virtual LCD (16 digits x 2 lines) in the "Host Information" area displays the POST codes and
status message.
When POST detects an error, the POST error code is displayed on the virtual LCD upon completion
of POST. See the table for POST error codes for details.
POWER ON
ATTENTION
Virtual LCD
Status indicators
Message send from BIOS
Message send from BMC
Example:
Messages displayed on upper line (BIOS message)
On-screen message
Description
Action
XX BIOS Rev YYYY
POST in progress.
XX: POST code, YYYY: BIOS version
Wait until POST completes.
Prepare To Boot
POST completes normally.
Mem Reconfigured
POST completes with memory degraded.
Contact your service
representative.
Mem Err Disable
A correctable memory error frequently
occurred.
CPU Reconfigured
POST completes with processor
degraded.
Memory C-Err XX
A correctable error frequently occurs in
DIMM #XX.
Memory U-Err XX
An uncorrectable error has occurred in
DIMM #XX.
PCI Bus SERR XX
A SERR has occurred in the PCI bus XX.
PCI Bus PERR XX
A PERR has occurred in the PCI bus XX.
Chipset Err XXXX
A chipset error occurred.
Summary of Contents for N8100-14522F
Page 16: ...x This page is intentionally left blank...
Page 122: ...4 54 Configuring Your Server This page is intentionally left blank...
Page 178: ...6 22 Installing and Using Utilities This page is intentionally left blank...
Page 190: ...7 12 Maintenance This page is intentionally left blank...
Page 254: ...A 2 Specifications This page is intentionally left blank...
Page 262: ...C 2 IRQ This page is intentionally left blank...
Page 316: ...F 2 Using a Client Computer Which Has a CD Drive This page is intentionally left blank...
Page 320: ...G 4 Product Configuration Record Table This page is intentionally left blank...