NOTE: The function related to pressing the key briefly is performed by pressing the key which will activate
the function assigned to it.On the other hand, to perform the function carried out when the key is held down
longer, press the key until the relative function is started. The buzzer will ring shortly to signal the function
has started.
NOTE: Warm-up: When the equipment has not been used for a prolonged period (more than 3 months) or
when turned on for the first time, a number of emissions with short times (0.01-0.02 sec.) are recommended
and then some pictures with 0.1 sec. intervals to better stabilize the operation of the x-ray tube before using
it.
3.4. CHECKING THE PARAMETERS
Before actually taking an exposure, make sure the exposure parameters for the examination in progress are correctly
set:
- Controlling the type of collimator selected.
Make sure the cone icon shown on the handheld matches the desired cone:
ICON
ON: indicates that the x-ray unit is using the built in round cone (diameter 60mm, focal spot-skin
distance 20cm).
ICON
OFF: indicates that the external removable rectangular or round cone is attached to the x-ray device
(source-skin distance 30cm).
Refer to paragraph 5.3 to set the type of movable collimator used.
NOTE: After the rectangular collimator (12”) has been attached or detached, the icon and set exposure
times will automatically be modified within a few seconds.
- Checking the selected body build.
-
“Child” selected: indicates the x-ray unit is set for patients with small builds.
-
“Adult” selected: indicates the x-ray unit is set for patients with average-large builds.
Average/large build (ADULT) selected
Small build (child) selected
NOTE: After the change has been made, the preset exposure times will automatically be modified.
- Checking the selected type of intraoral exam.
Upper molars
Lower incisors
Upper canines/bicuspids or rear
”bite-wing”
Lower canines/bicuspids
Upper incisors
or front ”bitewing”
Lower molars
Summary of Contents for RX DC
Page 1: ...97050850 Rev 12 15 10 myray RX DC RX DC I IT EN FR ES PL RU ...
Page 2: ...2 ISTRUZIONI PER L USO IT ITALIANO ...
Page 4: ...4 ISTRUZIONI PER L USO IT ...
Page 29: ...IT ISTRUZIONI PER L USO 29 ...
Page 31: ...IT ISTRUZIONI PER L USO 31 ...
Page 34: ...34 ISTRUZIONI PER L USO IT ...
Page 52: ...52 ISTRUZIONI PER L USO IT ...
Page 56: ...56 OPERATOR S MANUAL EN ...
Page 81: ...EN OPERATOR S MANUAL 81 ...
Page 83: ...EN OPERATOR S MANUAL 83 ...
Page 85: ...EN OPERATOR S MANUAL 85 11 3 XT VERSION All dimensions are expressed in millimeters inches ...
Page 86: ...86 OPERATOR S MANUAL EN ...
Page 104: ...104 OPERATOR S MANUAL EN ...
Page 108: ...108 INSTRUCTIONS D UTILISATION FR ...
Page 133: ...FR INSTRUCTIONS D UTILISATION 133 ...
Page 137: ...FR INSTRUCTIONS D UTILISATION 137 ...
Page 156: ...156 INSTRUCTIONS D UTILISATION FR ...
Page 160: ...160 INSTRUCCIONES DE USO ES ...
Page 187: ...ES INSTRUCCIONES DE USO 187 ...
Page 206: ...206 INSTRUCCIONES DE USO ES ...
Page 210: ...210 INSTRUKCJA OBSŁUGI PL ...
Page 236: ...236 INSTRUKCJA OBSŁUGI PL 11 3 WERSJA XT Wszystkie wymiary wyrażone są w milimetrach calach ...
Page 237: ...PL INSTRUKCJA OBSŁUGI 237 ...
Page 256: ...256 INSTRUKCJA OBSŁUGI PL ...
Page 260: ...260 ИНСТРУКЦИИ ПО ПРИМЕНЕНИЮ RU ...
Page 286: ...286 ИНСТРУКЦИИ ПО ПРИМЕНЕНИЮ RU 11 3 ВАРИАНТ XT Все размеры выражены в миллиметрах дюймах ...
Page 287: ...RU ИНСТРУКЦИИ ПО ПРИМЕНЕНИЮ 287 ...
Page 306: ...306 ИНСТРУКЦИИ ПО ПРИМЕНЕНИЮ RU ...
Page 309: ......