Notes on Parameters in General
Set parameters to determine the operating condition of the positioning unit.
The positioning unit can satisfy diversified needs through parameter setting in accordance with
the operation specifications and the control specifications.
Parameters are mainly classified into the following three types.
•
Positioning parameters (PARA. 0 ~)
Determine the units, the speed, etc. for positioning control.
•
I/O control parameters (PARA. 30 ~)
Determine the contents related to the I/Os of the positioning unit such as the method of
specifying the program No., the destination of the m code, etc.
•
System parameters (PARA. 100 ~)
Determine the memory size of the program, the number of file registers, etc.
In the FX
2N
-20GM, the positioning parameters and the I/O control parameters for independent
2-axis operation must be set for each of the X and Y axes. The parameters for simultaneous 2-
axis operation need only be set for the X axis. The settings for the Y axis are not required. In
the FX
2N
-10GM, the parameters must be set for one axis (the X axis) exclusively.
Peripheral units
E-TP teaching panel
FX-PCK-KIT-98/GM personal
computer software
FX-30DU-GM data access unit
Parameter memory
Special data registers
Positioning programs
Write
Read / Use
Overwrite
Power turned ON. MANU
to AUTO.
FX Series Positioning Controllers
Summary of Contents for FX2N-10GM
Page 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Page 4: ...FX Series Positioning Controllers ii ...
Page 6: ...FX Series Positioning Controllers iv ...
Page 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Page 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Page 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Page 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...