FX Series Positioning Controllers
Program format 5
5-34
Interrupt Drive Instructions
The inputs shown in the table below are assigned as the stop commands and deceleration
commands for interrupt drive control.
Because these inputs are treated as general-purpose inputs and can also be used with a man-
ual pulse generator they may not be available. (Refer to PARA. 39 (manual pulse generator)
described in Section 4.4.3.)
Table 5.15: Interrupt Drive Instructions
Input
FX
2N
-10GM
FX
2N
-20GM
X00
cod 72 : x axis speed-change input
cod 72 : x axis speed-change input
X01
cod 72 : x axis stop input
cod 72 : x axis stop input
X02
cod 71 : x axis
cod 72 : y axis speed-change input
X03
cod 31
cod 72 : y axis stop input
X04
cod 71 : x axis
X05
cod 71 : y axis
X06
cod 31 : Simultaneous 2-axis
Summary of Contents for FX2N-10GM