FX Series Positioning Controllers
Parameters 4
4-4
P
o
s
iti
oni
ng
par
am
ete
rs
19
DOG input logic
0: Normally open contact (A - contact)
0
1: Normally closed contact (B - contact)
20
LS logic
0: Normally open contact (A - contact)
0
1: Normally closed contact (B - contact)
21
Error judgement time 0 to 5,000 ms (When "0" is set, servo end check is invalid.)
0
22
Servo ready check
0: Valid, 1: Invalid
1
23
Stop mode
0, 4:Disables stop command.
1
1:
Enables remaining distance drive. (Jumps to END
instruction during interpolation operation.)
2:
Ignores remaining distance. (Jumps to END
instruction during interpolation operation.)
3, 7:Ignores remaining distance, and jumps to END
instruction.
5:
Performs remaining distance drive (including inter-
polation operation).
6:
Ignores remaining distance. (Jumps to NEXT
instruction during interpolation operation.)
24
Electrical zero point
address
-999,999 to + 999,999 [PLS]
0
25
Software limit (large)
-2,147,483,648 to +2,147,483,647
Software limit is invalid in case of "PARA. 25
≤
PARA. 26".
0
26
Software limit (small)
-2,147,483,648 to +2,147,483,647
Software limit is invalid in case of "PARA. 25
≤
PARA. 26".
0
Table 4.1: Parameter List
PARA.
No.
Item
Description ([ ]: unit)
Initial
value
Summary of Contents for FX2N-10GM
Page 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Page 4: ...FX Series Positioning Controllers ii ...
Page 6: ...FX Series Positioning Controllers iv ...
Page 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Page 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Page 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Page 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...