FX Series Positioning Controllers
Special auxiliary relays and Special data registers 6
6-5
Attribute
R:
This special auxiliary relay can be used only for read. You should not write it.
R/W: This special auxiliary relay can be used both for write and read. You can turn off M9144
and M9145 by the RST instruction.
*1 Both the X and Y axes operate simultaneously in simultaneous 2-axis operation.
*2 The zero point return completion flags (M9057 and M9089) do not turn on even if absolute
position detection is finished.
When you would like to use a flag to indicate that absolute position detection is finished, use
the current value establishment flags (M9144 and M9145). (The current value establish-
ment flags are not reset by return to the zero point.)
*3 Not defined in the FX
2N
-10GM
M9144
M9145
R/W
Present value establish flag *2 (This is set when zero return
or absolute position detection is performed once and reset
when the power is turned OFF).
M9146 to M9159
Not defined.
M9163
M9164
R/W
When the INC instruction is
executed, the compensation
data of cod73 to cod75
instruction is desire garded.
M9165 to M9175
Not defined.
Table 6.2: Special auxiliary relays list
X axis
Y axis
Subtask Attribute
Description
Summary of Contents for FX2N-10GM
Page 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Page 4: ...FX Series Positioning Controllers ii ...
Page 6: ...FX Series Positioning Controllers iv ...
Page 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Page 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Page 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Page 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...