Global error
: The error indication is performed for the both axes even if the error has
occurred in only either the X or Y axis. And the both axes stop.
Local error
: The error indication is performed for only the axis in which the error has
occurred. During simultaneous 2-axis operation, the both axes stop.
During independent 2-axis operation, only the axis in which the error has
occurred stops.
Program
error
3008
Repeat instruction fault
Nest levels exceeds 15
piles. Or, the RPT does
not correspond to the
label of the RPTEND.
Adjust nest levels to
15 piles or less.
Moreover, please
confirm the repeti-
tion instruction.
Global error
Local error
3009
O.N.P The number is
defective.
The O.N.P number outside
a set range is specified.
Confirm whether
there is same num-
ber.
3010
Axis set defect
Two axes exist together to
the program of two inde-
pendent axes simulta-
neously.
Unite programs.
Global error
External
errors
(LED
flashes.)
4002
Servo end error
The positioning comple-
tion signal is not received
from the motor amplifier.
Check PARA 21 and
the wiring.
Local error
Local error
4003
Servo ready error
The preparation comple-
tion signal is not received
from the motor amplifier.
Check PARA 22 and
the wiring.
4004
Limit switch actuated
Check PARA 20,
check the limit logic,
then check the wir-
ing.
4006
ABS data transfer error
Confirm PARA.50 to
52 and wiring.
Local error
Local error
Critical
error
9000
Memory error
If the same error
occurs again even
after turning OFF
and ON the power,
repair is required.
Contact the Mitsub-
ishi Service Center.
Global error
Global error
9001
Sum check error
9002
Watchdog timer error
(CPU-E LED is lit.)
9003
Hardware error
Table 10.3: Error code list
Error
category
Error
code
Details
Reset
Simultaneous
2-axis mode
Independent
2-axis mode
Summary of Contents for FX2N-10GM
Page 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Page 4: ...FX Series Positioning Controllers ii ...
Page 6: ...FX Series Positioning Controllers iv ...
Page 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Page 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Page 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Page 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...