FX Series Positioning Controllers
Special auxiliary relays and Special data registers 6
6-8
Attribute
R:
This data register can be used only for read. You should not write it.
R/W: This data register can be used both for write and read. When reading or writing data,
use a 16-bit instruction for a data register classified as "S", or a 32-bit instruction for a
data register classified as "D".
*1 In simultaneous 2-axis mode (available only in the FX
2N
-20GM), the special D for the X axis
is valid and the special D for the Y axis is ignored.
*2 In simultaneous 2-axis mode (available only in the FX
2N
-20GM), the same data is saved in
the special D for the X axis and the special D for the Y axis.
*3 Not defined in the FX
2N
-10GM.
Special data registers for current position data
Special data registers "D9005 and D9004" and "D9015 and D9014" shown in the previous
page store the current position data based on the practical unit set in PARA. 3.
You can write numeric data to these data registers while the positioning unit is ready (in the
AUTO or MANU mode) and is not waiting for remaining distance drive. When writing data, use
32-bit instructions.
On the other hand, special data registers "D9075 and D9074" and "D9095 and D9094" indi-
cating the current position converted into pulses can be used only for read, and their data auto-
matically changes in accordance with changes in the data stored in data registers "D9005 and
D9004" and "D9015 and D9014".
D9140
R/W
[S]
Index register. V0
D9141
Index register. V1
D9142
Index register. V2
D9143
Index register. V3
D9144
Index register. V4
D9145
Index register. V5
D9146
Index register. V6
D9147
Index register. V7
D9149
D9148
[D]
Index register. Z0
D9151
D9150
Index register. Z1
D9153
D9152
Index register. Z2
D9155
D9154
Index register. Z3
D9157
D9156
Index register. Z4
D9159
D9158
Index register. Z5
D9161
D9160
Index register. Z6
D9163
D9162
Index register. Z7
D9164 to D9199
Not defined.
Table 6.3:
Special data registers list
X axis
Y axis
Subtask
Attribute
Description
Upper
Lower
Upper
Lower
Upper
Lower
Direction of
forwarding
Instruc-
tion form
Summary of Contents for FX2N-10GM
Page 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Page 4: ...FX Series Positioning Controllers ii ...
Page 6: ...FX Series Positioning Controllers iv ...
Page 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Page 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Page 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...