FX Series Positioning Controllers
Introduction 1
1-24
1.7
Terminal Block
A terminal block converts the I/O area of a positioning unit or a connector type extension block
from a connector into a terminal block.
The following terminal blocks are available.
FX-16E-TB
: For both input and output, 16 points, can be connected to
positioning unit and extension block
FX-32E-TB
: For both input and output, 32 points, can be connected to
positioning unit and extension block
FX-16E-A1-TB
: For only AC input, 16 points, can be connected to extension
block (cannot be connected to positioning unit)
FX-16EY
…
-TB (
…
= R, S or T) : For only output, 16 points, can be connected to extension
block (cannot be connected to positioning unit)
FX-16EYT-H-TB
: For only output, 16 points, can be connected to extension
block (cannot be connected to positioning unit)
You can use a terminal block for only AC input or for only output to convert a connector type
extension block connected to the FX
2N
-20GM into a terminal block. Have in mind that you can-
not connect such a terminal block to the I/O area of the positioning unit.
For the details of terminal blocks, refer to an instruction manual offered together with each ter-
minal block.
1.7.1
Outside dimensions
0
1
2
3
COM
COM
4
5
6
7
4
5
COM
7
COM
1
0
1
2
3
COM
COM
4
5
6
COM
COM
0
1
2
3
COM
COM
MITSUBISHI
FX-32E-TB
CN1
CN2
CN1
CN2
4
55
150
45
CN2
CN2
CN1
Lightly pull a hook to
attach/remove a terminal
block to/from a DIN rail.
DIN rail groove
(width: 35 mm)
CN1
FX-32E-TB
Terminal screw M3.5
1
0
1
2
3
COM
COM
4
5
6
7
COM
COM
24+
24-
Terminal screw M3.5
4
55
150
Output indication
LEDs
(only in output type)
FX-16E-TB
FX-16EY
¨
-TB
FX-16EYT-H-TB
(
¨
=R,S,T)
FX-16E-A1-TB
Summary of Contents for FX2N-10GM
Page 1: ...HARDWARE PROGRAMMING MANUAL FX2N 10GM FX2N 20GM ...
Page 4: ...FX Series Positioning Controllers ii ...
Page 6: ...FX Series Positioning Controllers iv ...
Page 46: ...FX Series Positioning Controllers Introduction 1 1 34 MEMO ...
Page 76: ...FX Series Positioning Controllers Wiring 3 3 24 MEMO ...
Page 222: ...FX Series Positioning Controllers Operation Maintenance and Inspection 8 8 18 MEMO ...
Page 256: ...FX Series Positioning Controllers Program Examples 9 9 34 MEMO ...