background image

PR & PR Plus General Information 

The Haldex Precision Response (PR & PR Plus) Height Control Valves (HCV) automatically add and exhaust 
air from any air suspension to maintain a constant static design ride height.  The PR line of HCV’s are 
perfect for light to heavy duty applications and can be installed on rear air suspension, cab air suspension 
and front air suspension applications.  The PR and PR Plus line of HCV’s offer an array of fittings, manifolds 
and integrated dump valve options.  The PR and PR Plus HCV can be used in left or right hand installations 
with short or long control arm configurations. The Haldex line of PR height control valves have an industry 
leading deadzone, can operate in hot and cold environments and decrease air consumption 

NOTE:

 The Haldex PR & PR Plus HCV(s) can be interchanged with other brands of height control valves.    

Be sure to read instructions carefully for proper replacement and installation.  

Before You Get Started 

IMPORTANT: 

The HCV and linkage are designed to maintain the vehicle ride height as loads increase and 

decrease. Proper setup of the PR and PR Plus HCV(s) is critical to system performance. Prior to any assembly 
or disassembly, please read all instructions. Should you feel unable to properly perform the installation or 
adjustments of a Haldex PR or PR Plus HCV contact Haldex Technical Services or have a certified mechanic 
install or adjust the valve. 

CAUTION: 

Incorrect installation of any HCV and associated components can impair suspension and 

vehicle performance. It is extremely important that the original equipment manufacturer’s specifications of 
a one or two HCV system be followed when installing an air control system. Refer to vehicle and suspension 
manufacturer’s instructions for recommended valve location and ride height. 

DO NOT

 install a single height control valve of any type if the suspension or vehicle manufacturer        

specifies a two height control valve installation. 

DO NOT

 use a time delay valve with a PR or PR Plus HCV on the same vehicle. 

DO NOT

 use antifreeze or other solvents in an air supply line. Use of solvents or antifreeze can damage 

seals and void the valve warranty. 

NOTE:

 Conducting routine air system maintenance can help prevent any damage to air system             

components.  Never introduce foreign chemicals into any air system.  Drain all moisture from air reservoirs 
at regular intervals. 

ALWAYS

 use a Pressure Protection Valve (PPV) and filter such as the Haldex Part Number 90554107. 

Attach PPV directly to the air reservoir for supply to the PR & PR Plus HCV. 

Installation 
Guide  

L31231 

2/10  

Figure 1 

 

Installation Instructions for the 
PR and PR Plus Height Control Valve 

 

Reference Dimension Details for PR Plus HCV  

Summary of Contents for PR

Page 1: ...rm the installation or adjustments of a Haldex PR or PR Plus HCV contact Haldex Technical Services or have a certified mechanic install or adjust the valve CAUTION Incorrect installation of any HCV an...

Page 2: ...pound If recommended fittings are not available use a drop of oil or thread locker Use small amounts of sealant on threads only DO NOT use Teflon tape or pipe sealing compound 4 Mount the PR PR Plus H...

Page 3: ...of service NOTE A small amount of air may escape from the exhaust located under the interface cap this is normal and should not cause alarm or require replacement of the valve NOTE If two valves are u...

Page 4: ...ime without notice This document and other information from Haldex its subsidiaries and authorized distributors provide product and or system options for further investigation by users having technica...

Page 5: ...samblaje lea todas las instrucciones Si considera que no est capacitado para realizar la instalaci n o ajustes de HCV PR o PR Plus de Haldex comun quese con Servicio t cnico de Haldex o solicite que u...

Page 6: ...ceite o sellador de roscas Utilice peque as cantidades de sellador s lo en las roscas NO utilice cinta de tefl n o un compuesto para sellar tubos 4 Coloque HCV PR y PR Plus sobre el riel del marco o u...

Page 7: ...tico y permanecer cerca de la altura de recorrido durante los per odos cortos de servicio Un sistema de suspensi n neum tica se puede desinflar durante per odos fuera de servicio NOTA Una peque a cant...

Page 8: ...er sticas de productos especificaciones dise os disponibilidad y asignaci n de precios est n sujetos a cambio de Haldex y sus subsidiarias en cualquier momento sin previo aviso Este documento y otra i...