Monitoring of dedicated functions
ROLL TO ROLL FUNCTION RELATED PARAMETERS
181
9
9
ROLL TO ROLL FUNCTION RELATED
PARAMETERS
9.1
Monitoring of dedicated functions
9.1.1
Monitoring of roll to roll dedicated functions
The monitor item and the frequency setting displayed on the operation panel can be switched among the winding diameter,
line speed command, etc.
Monitoring on the operation panel or via communication
Purpose
Parameter to set
Refer to
page
To monitor roll to roll dedicated
functions
Monitoring of roll to roll
dedicated functions
(operation panel)
P.M100 to P.M104
Pr.52, Pr.774 to
Pr.776, Pr.992
Monitoring of roll to roll
dedicated functions
(analog output)
P.M300, P.M301
Pr.54, Pr.158
To use negative output for
monitoring
Negative output
selection for monitoring
P.M044
Pr.290
To select the polarity (positive or
negative) of the signal output
through terminal DA1.
Terminal DA1 output
polarity selection
P.R450
Pr.159
To set reference conditions (display
unit, full-scale value, etc.) for
monitoring
Monitor reference
P.R005, P.R201,
P.R301,
P.R400 to P.R402,
P.M040, P.M042
Pr.55, Pr.276,
Pr.358, Pr.866,
Pr.1262, Pr.1280,
Pr.1281, Pr.1401
Monitor item
Unit
Pr.52,
Pr.774
to
Pr.776,
Pr.992
RS-485
communication
dedicated
monitor
(hexadecimal)
MODBUS
RTU real time
monitor
Negative
indication
(-)
Description
Refer
to
page
Frequency / motor
speed setting
0.01 Hz
5
H05
40205
Displays the set frequency
—
Load meter
0.1%
17
H11
40217
Displays torque current as a
percentage, considering
Pr.56
setting value as 100% (motor
rated torque is considered as
100% during Sensorless vector
and vector control).
—
Analog output
signal for dancer
tension control
0.1%
19
H13
40219
Dancer tension command value
Winding diameter
0.1 mm
22
H16
40222
Winding diameter calculated in
the inverter
Line speed
command
0.1
26
H1A
40226
Line speed command value in
consideration of acceleration/
deceleration
Actual line speed
0.1
27
H1B
40227
Actual line speed
Dancer
compensation
speed
0.01 Hz
28
H1C
40228
Speed compensation amount
(manipulated amount) determined
by the PID calculation when
dancer feedback speed control is
valid
Winding length
(lower 4 digits)
1
29
H1D
40229
Winding length (lower 4 digits)
calculated in the inverter