Application examples
216
∗1
Adjustment parameter for adjusting the setting of another parameter.
Winding diameter change
increment amount limit
9999
2 mm
9999
2 mm
Setting
Pr.1247
= "9999 (initial value)"
disables the roll diameter calculation.
Be sure to change the setting from the initial
value for the roll diameter calculation.
Number of averaging for
winding diameter calculation
4
5
Use this parameter to enable the primary
delay filter relative to the result of the roll
diameter calculation.
1401
Tension command increment
0
1
0
1
1: Setting increment: 0.1 N, setting range: 0
to 1000 N
1405
Tension command gain
100 N
300 N
100 N
300 N
0 V corresponds to 0 N and 10 V
corresponds to 300 N.
1410
Motor inertia
0 kg·m
2
0 kg·m
2
Set these parameters to control tension
changes due to inertia torque during
acceleration/deceleration.
1411
Empty reel inertia
0 kg·m
2
0.01 kg·m
2
1412
Roll width
0 mm
50 mm
1413
Material specific gravity
0 g/cm
3
1.7 g/cm
3
1414
First acceleration time for
inertia compensation
15 s
5 s
1415
First deceleration time for
inertia compensation
15 s
5 s
1418
Inertia compensation cushion
time
0 s
0 s
Mechanical loss setting
frequency bias
1000%
1001.5%
Set the frequency and the compensation
value for each setting of mechanical loss.
Use these parameters when mechanical
losses are large or variable due to hard
acceleration/deceleration.
Mechanical loss setting
frequency 1
9999
1 Hz
Mechanical loss 1
1000%
1001.5%
Mechanical loss setting
frequency 2
9999
6.67 Hz
Mechanical loss 2
1000%
1002%
Mechanical loss setting
frequency 3
9999
16.67 Hz
Mechanical loss 3
1000%
1002.5%
Mechanical loss setting
frequency 4
9999
50 Hz
Mechanical loss 4
1000%
1003.5%
Mechanical loss setting
frequency 5
9999
93.33 Hz
Mechanical loss 5
1000%
1004.5%
Pr.
Parameter name
Initial
value
Setting value
Remarks
Unwinding
roller
Intermediate
roller
Winding
roller
Summary of Contents for A800 Plus Series