Winding diameter calculation setting
WINDING DIAMETER COMPENSATION FUNCTION
161
8
8.2.2
Basic setting for winding diameter calculation
Block diagram
Pr.
Name
Initial value
Setting
range
Description
1243
R600
Gear ratio numerator
(follower side)
1
1 to 65534
Set a gear ratio for a reduction-gear-equipped motor.
1244
R601
Gear ratio denominator
(driver side)
1
1 to 65534
1247
R000
Winding diameter change
increment amount limit
9999
0 to 9.998 mm
Set the maximum amount of change in each winding
diameter calculation.
9999
Winding diameter calculation invalid
1248
R001
Winding diameter change
limit disable time
0 s
0 to 100 s
Set the waiting time to start limiting the change
increment amount after the winding diameter
calculation is started.
Pr.362
Terminal 4
Terminal 2
Encoder pulse train input
(FR-A8AP/A8AL)
Encoder pulse train input
(FR-A8TP)
Terminal JOG single-phase
pulse train input
Line speed
command selection
Terminal 6
Terminal 1
4
3
0
1
6
5
Pr.291
= 0, 10, 20
Pr.291
=
1, 11, 21, 100
Pr.862
= 1
Pr.284
Pr.362
Pr.862
=
0
Input pulse
Pr.384
Pulse train calibration
Pr.279
,
Pr.281 to Pr.283
Pulse train calibration
Pr.279
,
Pr.281 to Pr.283
Pulse train calibration
Pr.279
,
Pr.281 to Pr.283
Primary delay filter
Pr.284
Primary delay filter
Pr.284
Primary delay filter
2
7
Analog calibration
Pr.278 to Pr.281
Pr.74
,
Pr.822
,
Pr.832
Primary delay filter
3 to 6
9999
FR-A8AL pulse train input (PP, NP)
Actual line speed
Unit switchover
Pr.358
Line speed
acceleration/deceleration
0
0