Dancer feedback speed control details
93
3
Block diagram
Connection diagram
∗1
Terminal 6 is equipped to the plug-in option FR-A8AZ.
1288
R510
Data table winding diameter 1
9999
0 to 6553 mm,
9999
Set the data table profile for the taper mode selection.
1289
R511
Data table taper ratio 1
0%
0 to 100%
1290
R512
Data table winding diameter 2
9999
0 to 6553 mm,
9999
1291
R513
Data table taper ratio 2
0%
0 to 100%
1292
R514
Data table winding diameter 3
9999
0 to 6553 mm,
9999
1293
R515
Data table taper ratio 3
0%
0 to 100%
1294
R516
Data table winding diameter 4
9999
0 to 6553 mm,
9999
1295
R517
Data table taper ratio 4
0%
0 to 100%
1296
R518
Data table winding diameter 5
9999
0 to 6553 mm,
9999
1297
R519
Data table taper ratio 5
0%
0 to 100%
Pr.
Name
Initial value
Setting
range
Description
Dancer tension setting
Pr.430
Analog terminal input
Pr.364
Pr.430
=9999
Pr.430
=9999
Pr.426
Pr.427
Dancer tension setting (%)
Dancer tension setting
(after calibration) (%)
0%
100%
Taper control
Analog output
signal for dancer
tension control
Taper ratio setting
Pr.1287
Analog terminal input
Pr.1285
Pr.1287
=9999
Pr.1287
=9999
Dancer tension setting
Taper function
Dancer tension
setting calibration
Clamping
FR-A800-R2R
2 (0 to 10 V)
Line speed command
1 (±10 V)
Dancer signal
10E
Tension setting
AM
5
Taper ratio setting
1 W 2 kΩ
1 W 2 kΩ
Electro-pneumatic
converter
4
5
6
∗1
FR-A8AZ
Input with the potentiometer
Pr.1285
="4"
Pr.1287
="9999"
Pr.158
="19"
Summary of Contents for A800 Plus Series