Winding diameter calculation setting
WINDING DIAMETER COMPENSATION FUNCTION
179
8
8.2.13
Speed control proportional gain selection
according to the winding diameter calculation
result
Speed control proportional gain at vector control and Real sensorless vector control can be changed based on the value
determined by winding diameter calculation.
First to fourth speed control proportional gain can be selected by the signal input.
Block diagram
Pr.
Name
Initial value
Setting
range
Description
639
R030
Speed control proportional
term applied diameter 1
9999
1 to 99%
Set the winding diameter (X1) used to select
proportional gain.
9999
Operates as 33%.
640
R031
Speed control proportional
term applied diameter 2
9999
1 to 99%
Set the winding diameter (X2) used to select
proportional gain.
9999
Operates as 66%.
641
R032
Speed control proportional
gain 1
9999
0 to 1000%,
9999
The proportional gain settings are switched according
to the winding diameter.
9999: Function disabled
642
R033
Speed control proportional
gain 2
9999
0 to 1000%,
9999
643
R034
Speed control proportional
gain 3
9999
0 to 1000%,
9999
644
R035
Speed control proportional
gain 4
9999
0 to 1000%,
9999
Pr.820
Pr.830
Frequency command
Winding diameter
Speed control proportional gain
RT-ON
RT-OFF
X124-ON
X124-OFF
Pr.639 to Pr.644