Parameter list (by parameter number)
29
2
1293
R515
Data table taper ratio 3
0 to 100%
0.1%
0%
1294
R516
Data table winding diameter 4
0 to 6553 mm, 9999
1 mm
9999
1295
R517
Data table taper ratio 4
0 to 100%
0.1%
0%
1296
R518
Data table winding diameter 5
0 to 6553 mm, 9999
1 mm
9999
1297
R519
Data table taper ratio 5
0 to 100%
0.1%
0%
1298
R007
Stored winding length (upper 4
digits)
0 to 9999(m
)
1(m
0(m
)
1299
R008
Stored winding length
increment
0 to 2
1
0
1300
to
1343
N500
to
N543
Communication option parameters. For details, refer to the Instruction Manual of the option.
1346
R424
Winding length detection (upper
4 digits)
0 to 9999(m
)
1(m
0(m
)
1348
G263
P/PI control switchover
frequency
0 to 400 Hz
0.01 Hz
0 Hz
─
1349
G264
Emergency stop operation
selection
0, 1, 10, 11
1
0
─
1350
to
1359
N550
to
N559
Communication option parameters. For details, refer to the Instruction Manual of the option.
1401
R301
Tension command increment
0 to 2
1
0
1402
R310
Tension command input voltage
bias
0 to 100%
0.1%
0%
1403
R311
Tension command bias
0 to 100 N
0 N
1404
R312
Tension command input voltage
gain
0 to 100%
0.1%
100%
1405
R313
Tension command gain
0 to 100 N
1406
R340
Commanded tension reduction
scaling factor during stall
condition
0 to 200%
0.1%
20%
1407
R341
Speed limit during stall
condition
0 to 60 Hz
0.01 Hz
1 Hz
1409
R343
Tension command cushion time
during stall condition
0 to 360 s, 9999
0.01 s
9999
1410
R530
Motor inertia
0 to 500 kg·m
2
, 9999
0.01 kg·m
2
0 kg·m
2
1411
R531
Empty reel inertia
0 to 500 kg·m
2
, 9999
0.01 kg·m
2
0 kg·m
2
1412
R532
Roll width
0 to 5000 mm
1 mm
0 mm
1413
R533
Material specific gravity
0 to 20 g/cm
3
0.001 g/cm
3
0 g/cm
3
1414
R535
First acceleration time for inertia
compensation
0 to 3600 s
0.1 s
15 s
1415
R536
First deceleration time for inertia
compensation
0 to 3600 s
0.1 s
15 s
1418
R534
Inertia compensation cushion
time
0 to 360 s
0.01 s
0 s
1419
R550
Mechanical loss setting
frequency bias
900 to 1100%
0.1%
1000%
1420
R551
Mechanical loss setting
frequency 1
0 to 400 Hz, 9999
0.01 Hz
9999
1421
R552
Mechanical loss 1
900 to 1100%
0.1%
1000%
1422
R553
Mechanical loss setting
frequency 2
0 to 400 Hz, 9999
0.01 Hz
9999
1423
R554
Mechanical loss 2
900 to 1100%
0.1%
1000%
1424
R555
Mechanical loss setting
frequency 3
0 to 400 Hz, 9999
0.01 Hz
9999
1425
R556
Mechanical loss 3
900 to 1100%
0.1%
1000%
1426
R557
Mechanical loss setting
frequency 4
0 to 400 Hz, 9999
0.01 Hz
9999
1427
R558
Mechanical loss 4
900 to 1100%
0.1%
1000%
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value Refer
to
page
Customer
setting
FM
CA
Summary of Contents for A800 Plus Series