Dancer feedback speed control details
92
3.5.16
Analog output signal function for dancer tension
setting
The dancer tension command can be used for controlling the dancer roll using an air cylinder. The dancer tension command
can be output through terminal FM/CA or terminal AM.
The dancer tension setting can be input by setting parameters or through an analog input terminal.
By setting the dancer tension, taper ratio, and winding diameter at taper start, the analog output signal for dancer tension
control can be calculated based on the winding diameter determined by winding diameter calculation.
Pr.
Name
Initial value
Setting
range
Description
74
T002
Input filter time constant
1
0 to 8
The primary delay filter time constant to the analog
input is selectable. A larger setting results in slower
response.
364
R411
Dancer tension setting input
selection
9999
3
The tension setting is input through terminal 2.
4
The tension setting is input through terminal 4.
5
The tension setting is input through terminal 1.
6
The tension setting is input through terminal 6 (FR-
A8AZ).
9999
No function
426
R412
Dancer tension setting bias
0%
0 to 200%
Set the bias tension.
427
R413
Dancer tension setting gain
100%
0 to 200%
Set the gain tension.
430
R410
Dancer tension setting
100
1 to 100
Set the maximum value for dancer tension setting.
9999
Tension setting through analog input terminal
826
T004
Torque setting filter 1
9999
0 to 5 s
Set the primary delay filter time constant to the analog
input.
9999
As set in
Pr.74
.
836
T006
Torque setting filter 2
9999
0 to 5 s
Second function of
Pr.826
(enabled when the RT signal
is ON)
9999
As set in
Pr.826
or
Pr.74
.
1284
R500
Taper mode selection
0
0
No taper
1
Linear taper profile
2
Hyperbolic taper profile 1
3
Hyperbolic taper profile 2
4
Data table profile
1285
R501
Taper setting analog input
selection
9999
3
The taper ratio is input through terminal 2.
4
The taper ratio is input through terminal 4.
5
The taper ratio is input through terminal 1.
6
The taper ratio is input through terminal 6 (FR-A8AZ).
9999
No function
1286
R503
Winding diameter at taper
start
9999
0 to 6553 mm
Set the winding diameter to start taper control.
9999
Taper control is started at the minimum winding
diameter.
1287
R502
Taper ratio setting
0
0 to 100%
Set the taper ratio.
9999
The taper ratio is set through the analog input terminal.