Monitoring of dedicated functions
186
ROLL TO ROLL FUNCTION RELATED PARAMETERS
Negative output selection for monitoring (Pr.290)
• A negative output can be selected for the monitor display of terminal AM (analog voltage output), the operation panel, and
a communication option. For the monitor items for which negative output is possible, refer to the monitor list.
∗1
RS-485 communication does not support the negative indication.
Terminal DA1 output polarity selection (Pr.159)
• When the FR-A8AZ is installed,
Pr.159 DA1 output sign selection
can be used to select the polarity of the output through
terminal DA1.
9.1.2
Monitor reference
Set the reference value for each item.
∗1
The increment varies depending on the
Pr.358
setting.
∗2
The setting varies with the
Pr.1401
setting.
Pr.290 setting
Negative output through
terminal AM
Negative indication on
operation panel
Negative indication on
communication options
0 (initial value)
—
—
—
1
Enabled
—
—
2
—
Enabled
—
3
Enabled
Enabled
—
4
—
—
Enabled
5
Enabled
—
Enabled
6
—
Enabled
Enabled
7
Enabled
Enabled
Enabled
—: Disabled (positive only)
Pr.159 setting
Output specification
Actual output sign
For positive monitor value
For negative monitor value
0 (initial value)
Standard output
Positive output
Negative output
1
Absolute value output
Positive output
Positive output (absolute value)
2
Reverse output
Negative output
Positive output
Pr.
Name
Initial value
Setting range
Description
FM
CA
55
M040
Frequency monitoring
reference
60 Hz
50 Hz
0 to 590 Hz
Set the full-scale value when the output frequency
monitor value is output through terminal FM, CA, or AM.
276
R400
Line speed monitoring
reference
1000 m/min
0 to 6553.4 m/min
Set the full-scale value when the line speed monitor
value is output through terminal FM, CA, or AM.
358
R201
Line speed unit
0
0
m/min
1
m/s
2
mm/min
3
mm/s
866
M042
Torque monitoring
reference
150%
0 to 400%
Set the full-scale value when the torque monitor value
is output through terminal FM, CA, or AM.
1262
R005
Winding length
increment
3
0
1 km
1
100 m
2
10 m
3
1 m
4
1 cm
5
1 mm
1280
R401
Winding diameter
monitoring reference
1000 mm
1 to 6553 mm
Set the full-scale value when the diameter monitor
value is output through terminal FM, CA, or AM.
1281
R402
Commanded tension
monitoring reference
100 N
0 to 100 N
Set the full-scale value of tension monitoring (tension
command, PID torque control actual tension, and PID
torque control manipulated tension) via terminal FM,
CA, or AM.
1401
R301
Tension command
increment
0
0
Setting increment: 0.01 N, setting range: 0 to 100 N
1
Setting increment: 0.1N, setting range: 0 to 1000N
2
Setting increment: 1N, setting range: 0 to 10000N