Parameter setting procedure for tension sensor feedback speed control
100
TENSION SENSOR FEEDBACK SPEED CONTROL
5
Mechanical specifications setting
Set the following parameters according to the specifications of the machine used. Refer to 10.4 (Application
examples) on
.
∗1
Set the parameter according to the specification of the machine used.
∗2
The increment applies when
Pr.21
= "0 (initial value)".
∗3
The increment applies when
Pr.358
= "0 (initial value)".
6
Tension feedback setting
Set the following parameters according to the tension feedback input method when the tension sensor is used.
∗1
The input specification in the initial setting is indicated. (Refer to
Pr.
Name
Setting
Intermediate
shaft
Winding/
unwinding
shaft
Remarks
1235
Maximum winding diameter
1
For the intermediate shaft, set the
roller (reel) diameter in millimeter in
both
Pr.1235
and
Pr.1236
.
1236
Minimum winding diameter
1
178 to
189
Input terminal function
selection
114
Set "114" for the X114 signal.
109
—
Set "109" to use the Stored winding
diameter clear (X109) signal.
117
—
Set "117" to use the Winding length
clear (X117) signal.
1230
Winding/unwinding selection
—
0: Winding shaft
1: Unwinding shaft
645
Winding diameter storage
selection
—
0: Not stored.
1: The present roll diameter is stored.
1247
Winding diameter change
increment amount limit
Set the maximum change in 0.001 mm
increments per roll diameter
calculation.
1243
Gear ratio numerator
(follower side)
Set a gear ratio when the motor shaft
has a reduction gear. (The increment
is 1 for each parameter.)
1244
Gear ratio denominator
(driver side)
7
Acceleration time
0 s
The increment is 0.1 seconds.
8
Deceleration time
0 s
394
First acceleration time for
line speed command
Setting is required in 0.1 second
increments when the cushion time is
not considered for the line speed
command.
395
First deceleration time for
line speed command
101
Second deceleration time
for line speed command
Set the time in 0.1 second increments
as required (for example, for rapid
deceleration).
Turn ON the X105
signal to enable the setting.
393
Line speed command
acceleration/deceleration
reference
Set the reference line speed (travel
amount per minute) in 0.1 m
increments for the acceleration/
deceleration time for the line speed
command.
1231
Material thickness d1
—
Setting is required in 0.001 mm
increments when thickness is used for
winding diameter calculation.
Pr.
Name
Setting
Input method
363
Dancer / tension sensor
feedback input selection
3
Terminal 2 (analog value: 0 to 100%) (0 to 5 VDC)
4
Terminal 4 (analog value: 20 to 100%) (4 to 20 mADC)
5
Terminal 1 (analog value: -100 to 100%) (0 to
±
10 VDC)
6
Terminal 6 (FR-A8AZ) (analog value: -100 to 100%) (0 to
±
10 VDC)
9999 (initial value) No function
Summary of Contents for A800 Plus Series