Winding diameter calculation setting
WINDING DIAMETER COMPENSATION FUNCTION
163
8
8.2.3
Winding diameter calculation using actual line
speed (actual line speed method)
The winding diameter is calculated from the actual line speed and the actual motor speed.
∗1
The increment varies depending on the
Pr.358
setting.
Pr.
Name
Initial
value
Setting range
Description
278
R051
Actual line speed voltage/
current gain
9999
0 to 100%
Set the converted % of the gain voltage (current) for
analog input.
9999
As set in the line speed command calibration setting.
279
R052
Actual line speed gain
9999
0 to 6553.4 m/min
Set the actual gain line speed for analog input.
9999
As set in the line speed command calibration setting.
280
R053
Actual line speed voltage/
current bias
9999
0 to 100%
Set the converted % of the bias voltage (current) for
analog input.
9999
As set in the line speed command calibration setting.
281
R054
Actual line speed bias
9999
0 to 6553.4 m/min
Set the actual bias line speed for analog input.
9999
As set in the line speed command calibration setting.
282
R055
Actual line speed pulse input
bias
9999
0 to 500 kpps
Set the bias side number of input pulses for pulse train
input.
9999
As set in the line speed command calibration setting.
283
R056
Actual line speed pulse input
gain
9999
0 to 500 kpps
Set the bias line speed for pulse train input.
9999
As set in the line speed command calibration setting.
284
R057
Actual line speed input filter
time constant
0.02 s
0 to 5 s
Set the time constant of the primary delay filter relative
to the pulse input value.
358
R201
Line speed unit
0
0
m/min
1
m/s
2
mm/min
3
mm/s
362
R050
Actual line speed input
selection
0
0
V* (line speed command)
1
Terminal JOG single-phase pulse train input
2
FR-A8AP/FR-A8AL/FR-A8TP encoder pulse train input
3
Terminal 2 (0 to 100%)
4
Terminal 4 (20 to 100%)
5
Terminal 1 (-100 to 100%)
6
Terminal 6 (FR-A8AZ) (-100 to 100%)
7
FR-A8AL single-phase pulse train input
9999
No function
384
D101
Input pulse division scaling
factor
0
0 to 250
Set the pulse division scaling factor for pulse train input
through terminal JOG.
1245
R042
Sampling time for winding
diameter calculation
9999
0.01 to 1 s
Set a sampling time for the winding diameter
calculation.
9999
Sampling time: About 5 ms