Dancer feedback speed control details
91
3
Overview of the reel change operation
• While the reel change function is activated, PID control and winding diameter calculation are disabled.
Function
Condition during reel change
PID control
Disabled (P, I, and D term values are cleared)
Winding diameter calculation
Disabled (winding diameter is held)
Start command
Y236
Line speed
X104
ON
ON
ON
Time
Line speed command
(after cushioning)
Target line speed command setting
Pr.620
PID control
Invalid
Valid
Winding diameter calculation
Invalid (winding diameter is held)
Valid
Fit to the originally set
target line speed