Tension sensorless torque control details
132
TENSION SENSORLESS TORQUE CONTROL
Motor inertia setting and empty reel inertia setting
• Motor inertia setting are determined as follows.
• Empty reel inertia setting are determined as follows.
Pr.1410
setting
RT
signal
Description
Setting range
Other
than
9999
—
Pr.1410
setting.
0 to 500 kg·m
2
9999
OFF
Pr.707
× 10^(-
Pr.724
)
(When "9999" is set in
Pr.707
or
Pr.724
, an internal value is used.)
10 × 10
-7
to 999 kg·m
2
ON
Pr.744
× 10^(-
Pr.745
)
(When "9999" is set in
Pr.744
or
Pr.745
, an internal value is used.)
Pr.1411
setting
Pr.754
setting
Description
Setting range
Other
than
9999
—
Pr.1411
setting.
0 to 500 kg·m
2
9999
0 to 7
Pr.753
× 10^(-
Pr.754
)
(When "9999" is set in
Pr.753
or
Pr.754
, inertia is set to 0.)
10 × 10
-7
to 999 × 10
4
kg·m
2
101 to
104
Pr.753
× 10^(
Pr.754
-100)
(When "9999" is set in
Pr.753
or
Pr.754
, inertia is set to 0.)
Summary of Contents for A800 Plus Series