Parameter list (by parameter number)
12
73
T000
Analog input selection
0 to 7, 10 to 17
1
1
74
T002
Input filter time constant
0 to 8
1
1
75
─
Reset selection/disconnected
PU detection/PU stop selection
0 to 3, 14 to 17, 1000 to
1003, 1014 to 1017
1
14
0 to 3, 14 to 17, 100 to
103, 114 to 117, 1000 to
1003, 1014 to 1017, 1100
to 1103, 1114 to 1117
E100
Reset selection
0 to 3
0
E101
Disconnected PU detection
0, 1
E102
PU stop selection
1
E107
Reset limit
0
0, 1
76
M510
Fault code output selection
0 to 2
1
0
77
E400
Parameter write selection
0 to 2
1
0
78
D020
Reverse rotation prevention
selection
0 to 2
1
0
79 D000
Operation mode
selection
0 to 4, 6, 7
1
0
80
C101
Motor capacity
0.4 to 55 kW, 9999
0.01 kW
9999
0.1 kW
81
C102
Number of motor poles
2, 4, 6, 8, 10, 12, 9999
1
9999
82
C125
Motor excitation current
0 to 500 A, 9999
0.01 A
9999
0.1 A
83
C104
Rated motor voltage
0 to 1000 V
0.1 V
200 V
400 V
84
C105
Rated motor frequency
10 to 400 Hz, 9999
0.01 Hz
9999
85
G201
Excitation current break point
0 to 400 Hz, 9999
0.01 Hz
9999
86
G202
Excitation current low-speed
scaling factor
0 to 300%, 9999
0.1%
9999
89
G932
Speed control gain (Advanced
magnetic flux vector)
0 to 200%, 9999
0.1%
9999
90
C120
Motor constant (R1)
0 to 50
Ω
0.001
Ω
9999
0 to 400 m
Ω
, 9999
0.01 m
91
C121
Motor constant (R2)
0 to 50
Ω
0.001
Ω
9999
0 to 400 m
Ω
, 9999
0.01 m
92
C122
Motor constant (L1)
0 to 6000 mH, 9999
0.1 mH
9999
0 to 400 mH, 9999
0.01 mH
93
C123
Motor constant (L2)
0 to 6000 mH, 9999
0.1 mH
9999
0 to 400 mH, 9999
0.01 mH
94
C124
Motor constant (X)
0 to 100%, 9999
0.1%
9999
0.01%
95
C111
Online auto tuning selection
0 to 2
1
0
96
C110
Auto tuning setting/status
0, 1, 11, 101
1
0
100
R253
Second acceleration time for
line speed command
0 to 3600 s
0.1 s
15 s
101
R254
Second deceleration time for
line speed command
0 to 3600 s
0.1 s
15 s
102
R255
Third acceleration time for line
speed command
0 to 3600 s
0.1 s
15 s
103
R256
Third deceleration time for line
speed command
0 to 3600 s
0.1 s
15 s
110
F030
Third acceleration/deceleration
time
0 to 3600 s, 9999
0.1 s
9999
111
F031
Third deceleration time
0 to 3600 s, 9999
0.1 s
9999
112
G020
Third torque boost
0 to 30%, 9999
0.1%
9999
113
G021
Third V/F (base frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
114
H602
Third stall prevention operation
level
0 to 400%
0.1%
150%
115
H603
Third stall prevention operation
frequency
0 to 590 Hz
0.01 Hz
0 Hz
116
M445
Third output frequency
detection
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
117
N020
PU communication station
number
0 to 31
1
0
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value Refer
to
page
Customer
setting
FM
CA
Simple
Simple
Simple
Summary of Contents for A800 Plus Series
Page 240: ...239 MEMO ...