Tension sensorless torque control details
126
TENSION SENSORLESS TORQUE CONTROL
Taper ratio setting input adjustment (Pr.829, Pr.902 to Pr.905, Pr.917,
Pr.918, Pr.926, Pr.927)
• When the taper ratio setting is input using analog input, use the following parameters to calibrate the input value of each
terminal. The taper ratios are calibrated for the 0% and 100% analog inputs. (The values for the 0% and 100% analog
inputs are fixed.)
∗1
The initial input range is 20 to 100%.
• When the taper ratio setting is input using analog input, the input value can be filtered using
Pr.829 Taper ratio setting
input filter time constant
.
Taper mode selection (Pr.1284)
• Use
Pr.1284 Taper mode selection
to select the tension reduction method (taper mode) for the taper function.
Input terminal
Calibration parameter
Terminal 2 (0 to 100%)
C3 (Pr.902), C4 (Pr.903)
Terminal 4 (0 to 100%)
C6 (Pr.904), C7 (Pr.905)
Terminal 1 (-100 to 100%)
C13 (Pr.917), C15 (Pr.918)
Terminal 6 (FR-A8AZ) (-100 to 100%)
C31 (Pr.926), C33 (Pr.927)
Pr.1284 setting
Taper mode
0
No taper
Constant tension command control
F
TP
= F*
F
TP
: Taper control tension command, F*: Tension command
Taper ratio setting (%)
100
0
10 V
Analog input value
Gain
C4(Pr.903)
C7(Pr.905)
C15(Pr.918)
C33(Pr.927)
-10 V
Bias
C3(Pr.902)
C6(Pr.904)
C13(Pr.917)
C31(Pr.926)
Tension command value
Winding diameter
Minimum
winding diameter
Maximum
winding diameter
Taper control tension command
Tension command