Parameter setting procedure for dancer feedback speed control
50
NOTE
• If the SF-V5RU (other than the 1500 r/min series) is used, be sure to perform auto tuning after setting "1, 13, or 14" in
Pr.71
and setting
Pr.83
and
Pr.84
.
• If
Pr.11 DC injection brake operation time
= "0" or
Pr.12 DC injection brake operation voltage
= "0", offline auto tuning is
performed considering
Pr.11
or
Pr.12
is set to the initial value.
• If the star connection or delta connection is incorrectly selected in
Pr.71
, Advanced magnetic flux vector control, Real
sensorless vector control and vector control are not performed normally.
• For tuning accuracy improvement, set the following parameters when the motor constants are known in advance.
∗4
The setting is valid only when a value other than "9999" is set in both
Pr.707 (Pr.744)
and
Pr.724 (Pr.745).
Motor
Pr.71 setting
Motor constant
parameter mH, %,
and A unit setting
Motor constant
parameter internal
data setting
Motor constant
parameter
Ω
, m
Ω
,
and A unit setting
Mitsubishi Electric standard
motor
Mitsubishi Electric high-
efficiency motor
SF-JR, SF-TH
0 (initial value)
3 (4)
—
SF-JR 4P 1.5 kW or lower
20
23 (24)
—
SF-HR
40
43 (44)
—
Others
0 (initial value)
3 (4)
—
Mitsubishi Electric constant-
torque motor
SF-JRCA 4P, SF-TH
(constant-torque)
1
13 (14)
—
SF-HRCA
50
53 (54)
—
Other (SF-JRC, etc.)
1
13 (14)
—
Mitsubishi Electric high-
performance energy-saving
motor with encoder
SF-PR-SC
70
73 (74)
—
Vector control dedicated
motor
SF-V5RU (1500 r/min series)
SF-THY
30
33 (34)
—
SF-V5RU (other than the
1500 r/min series)
1
13 (14)
—
Other manufacturer's
standard motor
—
0 (initial value)
3 (4)
5 (star connection
motor)
6 (delta connection
motor)
Other manufacturer's
constant-torque motor
—
1
13 (14)
15 (star connection
motor)
16 (delta connection
motor)
First
motor Pr.
Second
motor Pr.
Name
Mitsubishi Electric
motor
(SF-JR, SF-HR, SF-JRCA,
SF-HRCA, SF-V5RU)
Other motors
707
744
Motor inertia (integer)
9999 (initial value)
Motor inertia
Jm =
Pr.707
×
10^(-
Pr.724
) (kg·m
2
)
724
745
Motor inertia (exponent)
Summary of Contents for A800 Plus Series