Winding diameter calculation setting
WINDING DIAMETER COMPENSATION FUNCTION
171
8
8.2.9
Target winding diameter achieved
When the winding diameter calculated in the inverter is equal to or more than the parameter setting, the Target winding
diameter achieved (Y233) signal is output.
Target winding diameter achieved (Pr.648, Y233 signal)
• When the result of winding diameter calculation in the inverter is equal to or more than the
Pr.648 Target winding
diameter
setting, the Target winding diameter achieved (Y233) signal can be output.
• The Y233 output condition depends on whether the operation is winding or unwinding.
8.2.10
Winding diameter calculation at a start
When the dancer roll is moved from the upper/lower limit position to the target position at start, the present winding diameter
is calculated.
Pr.
Name
Initial value
Setting
range
Description
648
R420
Target winding diameter
1
1 to 6553
Set the winding diameter to output the Target winding
diameter achieved (Y233) signal.
Winding/unwinding
Y233 output condition
Winding
Output when the winding diameter reaches or exceeds the
Pr.648
setting.
Unwinding
Output when the winding diameter reaches or falls below the
Pr.648
setting.
Pr.
Name
Initial value
Setting
range
Description
133
R101
(A611)
PID action set point
500%
400 to 600%
Set the target position for the dancer roll.
1252
R070
Dancer lower limit position
400%
400 to 600%
The initial winding diameter calculation is performed
when the dancer roll position is equal to or lower than
the setting of this parameter.
1253
R071
Initial winding diameter
calculation deadband
1%
0 to 50%
Set the deadband on the lower limit position.
1254
R072
Initial winding diameter
calculation deadband 2
9999
0 to 50%
Set the deadband on the target position.
9999
The deadband on the target position is as set in
Pr.1253
.
1255
R073
Accumulated amount
9999
1 to 5000 mm
Set the accumulated amount.
8888
The initial winding diameter calculation is invalid. (When
the dancer roll position is equal to or lower than the
Pr.1252
setting, the dancer roll is lifted.)
9999
Initial winding diameter calculation invalid
1256
R074
Speed control P gain at start
60%
0 to 1000%
Set the speed control proportional gain during initial
winding diameter calculation at start.
1257
R075
Speed control integral time at
start
2 s
0 to 20 s
Set the speed control integral time during initial winding
diameter calculation at start.
1258
R076
Integral term limit at start
2.5%
0 to 100%
Set the integral action limit value during initial winding
diameter calculation at start.
1259
R077
PID term limit at start
2.5%
0 to 100%
Set the PID manipulated amount limit value during
initial winding diameter calculation at start.