Differences in the functions from the standard inverter
196
∗1
The
Pr.178 to Pr.189 (input terminal function selection)
setting is shown in the parentheses.
∗2
The
Pr.190 to Pr.196 (output terminal function selection)
setting is shown in the parentheses.
∗3
The monitor selection parameter setting is shown in the parentheses.
• The parameters related to cumulative pulse in the FR-A800-R2R are as follows, different from those in the FR-A800
standard inverters. The function of the parameters are the same as those of the FR-A800 standard inverters. (For details,
refer to the Instruction Manual (Detailed) of the FR-A800 inverter.)
NOTE
• Functions not mentioned above are the same as those of the FR-A800 standard inverter. (The functions added in and after
December 2017 are not supported.)
• For the details of general specifications, refer to the catalog or Instruction Manual of the FR-A800 inverter.
Brake sequence control
Pr.278 to Pr.284
,
Pr.639 to Pr.648
,
Pr.650
,
Pr.651
BRI (15)
BRI2 (45)
BOF (20)
BOF2 (22)
—
Electronic bypass sequence
Pr.135 to Pr.139
,
Pr.159
X95 (95)
X96 (96)
MC1 (17)
MC2 (18)
MC3 (19)
—
Stop frequency function
Pr.522
—
—
—
Stop-on-contact control
Pr.270
,
Pr.275
,
Pr.276
—
—
—
Load torque high-speed
frequency control
Pr.271 to Pr.274
X19 (19)
—
—
Anti-sway control function
Pr.1072 to Pr.1079
—
—
—
Traverse function
Pr.592 to Pr.597
X37 (37)
—
—
Strengthened excitation
deceleration
Pr.660 to Pr.662
—
—
—
Self power management
Pr.248
,
Pr.254
X94 (94)
—
—
SSCNET III communication
(FR-A8NS)
Pr.379
,
Pr.449
,
Pr.499
X85 (85)
X88 (88)
X89 (89)
—
SSCNET III communication
status (39)
FL remote communication
(FR-A8NF)
—
—
—
—
L
ON
W
ORKSR
communication
(FR-A8NL)
Pr.387 to Pr.392
—
—
—
Torque control by variable-
current limiter control
Pr.451
setting range change
("6 and 106" are deleted.)
Pr.800
setting range change
("6 and 106" are deleted.)
—
—
—
Second motor control method
selection
Pr.451
setting range change
("0 to 2 and 100 to 102" are deleted.)
—
—
—
4 mA input check
Pr.573
setting range change
("4" is deleted.)
Pr.777
is deleted.
—
—
—
Stop mode at communication
error
Pr.502
setting range change
("3 and 4" are deleted.)
Pr.779
is deleted.
—
—
—
Online auto tuning
Pr.574
setting range change
("2" is deleted.)
—
—
—
DC injection brake (zero speed
control and servo lock)
Pr.1299
—
—
—
JOG signal
Pr.338
(The JOG signal can be sent
through communication.)
JOGF (57)
JOGR (58)
—
—
Start count monitor
Pr.1410, Pr.1411
—
—
—
Changeover between inverter
and high power factor converter
Pr.328
—
—
—
Parameter information (when
the FR-LU08 is installed)
—
—
—
—
Parameter name
FR-A800 standard inverter
FR-A800-R2R series inverter
Cumulative pulse clear signal selection
Pr.635
Pr.755
Cumulative pulse division scaling factor
Pr.636
Pr.756
Control terminal option-Cumulative pulse
division scaling factor
Pr.637
Pr.757
Cumulative pulse storage
Pr.638
Pr.758
Function
Parameter
Input
signal
∗1
Output
signal
∗2
Monitor
∗3