Parameter setting procedure for tension sensor feedback speed control
TENSION SENSOR FEEDBACK SPEED CONTROL
99
4
4.4
Parameter setting procedure for tension
sensor feedback speed control
The following procedure shows the parameter setting example for the tension sensor feedback speed control.
4.4.1
Parameter setting procedure
1
Wiring
Perform secure wiring.
NOTE
• Do not feed the workpiece through the machine.
2
Control method selection
Select the control method according to the application and the motor.
∗1
For the control method, vector control is recommended.
∗2
Setting is required for a motor other than a Mitsubishi Electric motor (the SF-PR, SF-JR, SF-HR, SF-JRCA, SF-HRCA, or SF-V5RU (1500 r/min
series) motor).
NOTE
• Select Vector control method for regenerative driving in low-speed range (about 10 Hz or lower).
• For the parameter details, refer to the FR-A800 Instruction Manual (Detailed).
3
Offline auto tuning
Perform offline auto tuning as required. For offline auto tuning, refer to
.
After the offline auto tuning, perform the test run of the motor alone to make sure that no fault is found in the
motor's behavior.
4
Speed control gain adjustment
Adjust the speed control gain. Refer to
for the speed control gain adjustment.
Pr.
Name
71
Applied motor
9
Electronic thermal O/L relay
80
Motor capacity
81
Number of motor poles
83
Rated motor voltage
84
Rated motor frequency
800
Control method selection
810
Torque limit input method selection
359
Encoder rotation direction
369
Number of encoder pulses
707
Motor inertia (integer)
724
Motor inertia (exponent)
862
Encoder option selection
Pr.
Name
96
Auto tuning setting/status
Summary of Contents for A800 Plus Series