Operation command source and speed command source (Pr.338, Pr.339)
ROLL TO ROLL FUNCTION RELATED PARAMETERS
193
9
9.4
Operation command source and speed
command source (Pr.338, Pr.339)
• In the Network operation mode, the commands for the roll to roll function are sent through the external terminals or
communication as follows. (The signal assigned to the inverter differs depending on the input terminal function selection setting.)
EXT: Commands sent through external terminals are only valid.
NET: Commands sent via network are only valid.
Combined: Any command given via the external terminals or given through communication is valid.
—: Any commands sent through external terminals or via network are invalid.
NOTE
• For other signals, refer to the Instruction Manual (Detailed) of the FR-A800 inverter.
Pr.
Name
Setting range
Increment
Initial value
Remarks
338
Communication operation
command source
0, 1
1
0
0: NET command source
1: External command source
339
Communication speed
command source
0 to 2
1
0
0: NET command source
1: External command source 1
2: External command source 2
Command
sources
selection
Pr.338 Communication operation
command source
0: NET
1: external
Pr.339 Communication speed command
source
0: NET
1: EXT
2: EXT
0: NET
1: EXT
2: EXT
Fixed function
(terminal-
equivalent
function)
Line speed command sent via communication
NET
—
NET
NET
—
NET
Line speed command sent through an analog
terminal (
Pr.361
=
"
0
"
)
—
EXT
—
—
EXT
—
Line speed command sent through an analog
terminal (
Pr.361
=
"
3 to 6
"
)
EXT
EXT
Selectab
le fu
nctio
n
Pr
.1
78 to Pr
.189 se
ttin
g
0
RL
Low-speed operation command
NET
EXT
NET
EXT
1
RM
Middle-speed operation command
NET
EXT
NET
EXT
2
RH
High-speed operation command
NET
EXT
NET
EXT
5
JOG
Jog operation selection
NET
EXT
8
REX
15-speed selection
NET
EXT
NET
EXT
81
PGT
Tension PI gain tuning start / forced end
NET
EXT
100
X100
PID integral term reset input
NET
EXT
101
X101
PI control switchover
NET
EXT
102
X102
Offset displacement storage
NET
EXT
103
X103
Integral term activation selection
NET
EXT
104
X104
Reel change
NET
EXT
105
X105
Acceleration/deceleration time selection
1 for line speed command
NET
EXT
106
X106
Acceleration/deceleration time selection
2 for line speed command
NET
EXT
107
X107
Minimum/maximum winding diameter
selection 1
NET
EXT
108
X108
Minimum/maximum winding diameter
selection 2
NET
EXT
109
X109
Stored winding diameter clear
NET
EXT
111
X111
Inertia compensation acceleration
Combined
EXT
112
X112
Inertia compensation deceleration
Combined
EXT
113
X113
Inertia compensation second
acceleration/deceleration time
NET
EXT
114
X114
Tension control selection
Combined
EXT
115
X115
Winding diameter compensation selection
NET
EXT
116
X116
PID compensation disabled
NET
EXT
117
X117
Winding length clear
NET
EXT
120
X120
PID gain switchover 1
NET
EXT
121
X121
PID gain switchover 2
NET
EXT
122
X122
Winding diameter measurement
NET
EXT
123
X123
Stall mode trigger
NET
EXT
124
X124
Speed control proportional gain disabled
NET
EXT
125
X125
Line speed / tension command input
NET
EXT
126
X126
Two-way operation
NET
EXT
Summary of Contents for A800 Plus Series