Differences in the functions from the standard inverter
195
10
10
APPENDIX
10.1
Differences in the functions from the
standard inverter
• The following functions of the FR-A800 standard inverter are deleted in the FR-A800-R2R inverter. Parameters, I/O signals,
and monitors relative to the deleted functions are also deleted or used differently in the FR-A800-R2R inverter.
Function
Parameter
Input
signal
Output
signal
Monitor
PM motor control
Pr.373
,
Pr.702
,
Pr.706
,
Pr.711
,
Pr.712
,
Pr.717
,
Pr.721
,
Pr.725
,
Pr.738 to Pr.743
,
Pr.746
,
Pr.747
,
Pr.788
,
Pr.791
,
Pr.792
,
Pr.998
,
Pr.1002
,
Pr.1105, Pr.1412, Pr.1413
Pr.71
setting range change ("330,
333, 334, 8090, 8093, 8094, 9090,
9093, and 9094" are deleted.)
Pr.450
setting range change ("330,
333, 334, 8090, 8093, 8094, 9090,
9093, and 9094" are deleted.)
—
IPM (57)
—
PID control
Second PID
Pr.753 to Pr.758
,
Pr.765 to Pr.769
,
Pr.1136 to Pr.1149
X73 (73)
X78 (78)
X79 (79)
X80 (80)
Y50 (50)
Y52 (52)
Y54 (54)
FDN2 (200)
FUP2 (201)
RL2 (202)
PID2 (203)
SLEEP2 (204)
Y205 (205)
Second PID set point (92)
Second PID measured
value (93)
Second PID deviation (94)
Second PID measured
value 2 (95)
Second PID manipulated
amount (96)
Set point /
deviation /
measured value
input selection
Pr.609
,
Pr.610
Pr.128
setting range change
("10, 11, 20, 21, 42, 43, 50, 51, 60, 61,
70, 71, 80, 81, 90, 91, 100, 101, 1000,
1001, 1010, 1011, 2000, 2001, 2010,
2011" are deleted.)
X14 (14)
PID pre-charge
function
Pr.760 to Pr.764
X77 (77)
Y49 (49)
Y51 (51)
Y53 (53)
—
PID display unit
Pr.759
,
C42 (Pr.934)
,
C43 (Pr.934)
,
C44 (Pr.935)
,
C45 (Pr.935)
—
—
—
SLEEP function
Pr.575 to Pr.577
Pr.554
setting range change
("10 to 13" are deleted.)
Pr.1015
setting range change
("2, 10 to 12" are deleted.)
—
SLEEP (70)
—
Dancer control
Pr.1134
,
Pr.1135
—
—
Dancer main set speed (97)
Position control
Pr.419 to Pr.421
,
Pr.423 to Pr.427
,
Pr.429
,
Pr.446
,
Pr.464 to Pr.494
,
Pr.1220 to Pr.1290
,
Pr.1292 to Pr.1298
Pr.451
setting range change
("3 to 5, 13, 14, 103 to 105, 113, and
114" are deleted.)
Pr.800
setting range change
("3 to 5, 13, 14, 103 to 105, 113, and
114" are deleted.)
CLRN (59)
NP (68)
CLR (69)
X76 (76)
X84 (84)
X87 (87)
Y36 (36)
MEND (38)
ZA (56)
FP (60)
PBSY (61)
ZP (63)
RDY (84)
Position pulse (19)
Position command (lower)
(26)
Position command (upper)
(27)
Current position (lower) (28)
Current position (upper) (29)
Droop pulse (lower) (30)
Droop pulse (upper) (31)
Multi-revolution counter (75)
Orientation function
Pr.350 to Pr.358
,
Pr.360 to Pr.366
,
Pr.393 to Pr.399
,
Pr.829
X22 (22)
ORA (27)
ORM (28)
Orientation status (22)
Pulse monitor selection
Pr.430
—
—
—
Adjustable 5 points V/F
Pr.100 to Pr.109
Pr.71
setting range change
("2" is deleted.)
—
—
—
Remote function
Pr.59
—
—
—
Automatic acceleration/
deceleration
Pr.61 to Pr.64
,
Pr.292
,
Pr.293
—
—
—