Dancer feedback speed control details
60
3.5.3
Line speed command input
Set the line speed command input method. The selectable input methods include the following: parameter setting, analog
input, multi-speed setting input, and pulse input.
Pr.
Name
Initial value
Setting range
Description
350
R210
Line speed command
voltage/current bias
0%
0 to 100%
Set the converted % of the bias voltage (current) for
analog input.
351
R211
Line speed command bias
0 m/min
0 to 6553.4 m/min
Set the bias line speed for analog input.
352
R212
Line speed command
voltage/current gain
50%
0 to 100%
Set the converted % of the gain voltage (current) for
analog input.
353
R213
Line speed command gain
1000 m/min
9999
Set the gain line speed command value for analog
input.
354
R220
Line speed command
pulse input bias
0 kpps
0 to 500 kpps
Set the number of bias input pulses for pulse train
input.
355
R221
Line speed command
pulse input gain
100 kpps
0 to 500 kpps
Set the bias line speed command value for pulse train
input.
356
R222
Line speed command
digital input bias
0
0 to 65535
Set the number of gain input pulses for pulse train
input.
357
R223
Line speed command
digital input gain
65535
0 to 65535
Set the gain line speed command value for pulse train
input.
358
R201
Line speed unit
0
0
m/min
1
m/s
2
mm/min
3
mm/s
360
R202
Line speed command
value
0 m/min
0 to 6553.4 m/min
Set the line speed command value.
361
R200
Line speed command
input selection
9999
0
According to the priority of the speed command
sources.
1
Terminal JOG single-phase pulse train input
2
FR-A8AP/FR-A8AL/FR-A8TP encoder pulse train
input
3
Terminal 2 (0 to 100%)
4
Terminal 4 (20 to 100%)
5
Terminal 1 (-100 to 100%)
6
Terminal 6 (FR-A8AZ) (-100 to 100%)
7
FR-A8AL single-phase pulse train input
8
Line speed command according to the
Pr.360
setting
9999
No function
428
B009
Command pulse selection
0
0
Forward/Reverse pulse train
Negative logic
1
Pulse train + rotation direction sign
2
A/B phase pulse train
3
Forward/Reverse pulse train
Positive logic
4
Pulse train + rotation direction sign
5
A/B phase pulse train
622
R204
Line speed command for
starting
0 m/min
0 to 6553.4 m/min
Set the line speed command to start operation.
1265
R230
Line multi-speed setting
(high-speed)
0 m/min
0 to 6553.4 m/min
Set the line speed command value when the RH
signal is ON.
1266
R231
Line multi-speed setting
(middle-speed)
0 m/min
0 to 6553.4 m/min
Set the line speed command value when the RM
signal is ON.
1267
R232
Line multi-speed setting
(low-speed)
0 m/min
0 to 6553.4 m/min
Set the line speed command value when the RL
signal is ON.
Summary of Contents for A800 Plus Series