Parameter list (by function group)
35
2
H: Protective function parameters
Parameters to protect the motor and the inverter.
D304
to
D307
24
to
27
Multi-speed setting (4 speed to 7
speed)
─
D308
to
D315
232
to
239
Multi-speed setting (8 speed to 15
speed)
─
D400
804
Tension / Torque command
source selection
D401
805
Torque command value (RAM)
─
D402
806
Torque command value
(RAM,EEPROM)
─
D403
1114
Torque command reverse
selection
Pr.
group
Pr.
Name
Refer
to
page
H000
9
Electronic thermal O/L relay
─
H001
600
First free thermal reduction
frequency 1
─
H002
601
First free thermal reduction ratio
1
─
H003
602
First free thermal reduction
frequency 2
─
H004
603
First free thermal reduction ratio
2
─
H005
604
First free thermal reduction
frequency 3
─
H006
607
Motor permissible load level
─
H010
51
Second electronic thermal O/L
relay
─
H011
692
Second free thermal reduction
frequency 1
─
H012
693
Second free thermal reduction
ratio 1
─
H013
694
Second free thermal reduction
frequency 2
─
H014
695
Second free thermal reduction
ratio 2
─
H015
696
Second free thermal reduction
frequency 3
─
H016
608
Second motor permissible load
level
─
H020
561
PTC thermistor protection level
─
H021
1016
PTC thermistor protection
detection time
─
H022
876
Thermal protector input
─
H030
875
Fault definition
─
H100
244
Cooling fan operation selection
─
H101
249
Earth (ground) fault detection at
start
─
H102
598
Undervoltage level
─
H103
997
Fault initiation
─
H200
251
Output phase loss protection
selection
─
H201
872
Input phase loss protection
selection
─
H300
65
Retry selection
─
H301
67
Number of retries at fault
occurrence
─
H302
68
Retry waiting time
─
Pr.
group
Pr.
Name
Refer
to
page
H303
69
Retry count display erase
H400
1
Maximum frequency
H401
2
Minimum frequency
H402
18
High speed maximum frequency
H410
807
Speed limit selection
H411
808
Forward rotation speed limit/
speed limit
H412
809
Reverse rotation speed limit/
reverse-side speed limit
H414
1113
Speed limit method selection
H415
873
Speed limit
H416
285
Speed deviation excess detection
frequency
H417
853
Speed deviation time
H420
31
Frequency jump 1A
H421
32
Frequency jump 1B
H422
33
Frequency jump 2A
H423
34
Frequency jump 2B
H424
35
Frequency jump 3A
H425
36
Frequency jump 3B
H429
552
Frequency jump range
H500
22
Stall prevention operation level
(Torque limit level)
H501
156
Stall prevention operation
selection
H520
1480
Load characteristics
measurement mode
H521
1481
Load characteristics load
reference 1
H522
1482
Load characteristics load
reference 2
H523
1483
Load characteristics load
reference 3
H524
1484
Load characteristics load
reference 4
H525
1485
Load characteristics load
reference 5
H526
1486
Load characteristics maximum
frequency
H527
1487
Load characteristics minimum
frequency
H531
1488
Upper limit warning detection
width
H532
1489
Lower limit warning detection
width
H533
1490
Upper limit fault detection width
H534
1491
Lower limit fault detection width
H535
1492
Load status detection signal
delay time / load reference
measurement waiting time
H600
48
Second stall prevention operation
level
H601
49
Second stall prevention operation
frequency
H602
114
Third stall prevention operation
level
H603
115
Third stall prevention operation
frequency
H610
23
Stall prevention operation level
compensation factor at double
speed
H611
66
Stall prevention operation
reduction starting frequency
Pr.
group
Pr.
Name
Refer
to
page
Summary of Contents for A800 Plus Series