Monitoring of dedicated functions
182
ROLL TO ROLL FUNCTION RELATED PARAMETERS
∗1
To enable display with a minus sign, set
Pr.290 Monitor negative output selection
.)
∗2
When the negative indication is invalid, the value is indicated as an offset from 1000%.
Analog output
signal 2 for dancer
tension control
0.1%
30
H1E
40230
Dancer tension command value
Line speed pulse
monitor
0.01
kpps
31
H1F
40231
Pulse train input value (when the
actual line speed is input with
pulse signal)
PID set point
0.1%
52
H34
40252
Dancer roll set point
PID measured
value
0.1%
53
H35
40253
Dancer roll position
PID deviation
0.1%
54
H36
40254
Dancer roll deviation from set
point
Winding length
(upper 4 digits)
1
63
H3F
40263
Winding length (upper 4 digits)
calculated in the inverter
PID measured
value 2
0.1%
67
H43
40267
Dancer roll position. It is displayed
even if the dancer feedback speed
control operating conditions are
not satisfied while the dancer
feedback speed control is enabled
(
Pr.128
≠
"0").
Tension command
after taper
compensation
0.01 N /
0.1 N /
1 N
81
H51
40281
Commanded tension after taper
compensation
Winding diameter
compensation
torque command
0.1%
82
H52
40282
Commanded torque after winding
diameter compensation
—
Inertia
compensation
0.1%
83
H53
40283
Inertia compensation torque
Mechanical loss
compensation
0.1%
84
H54
40284
Mechanical loss compensation
value
Terminal 1 input
voltage
0.1 V
85
H55
40285
Voltage applied to terminal 1
Terminal 1 input
after calibration (%)
0.1%
86
H56
40286
Analog value input through
terminal 1 after calibration with
Pr.917
and
Pr.918
settings
PID manipulated
amount
0.1%
91
H5B
40291
PID manipulated amount
PID torque control
actual tension
0.01 (N)/
0.1 (N)/
1 (N)
92
H5C
40292
A tension value measured under
torque control for tension control
with PID control enabled
—
PID torque control
manipulated
tension
0.01 (N)/
0.1 (N)/
1 (N)
93
H5D
40293
A tension value manipulated
under torque control for tension
control with PID control enabled
—
Winding diameter
compensation
speed
0.01 Hz
97
H61
40297
Frequency (winding diameter
compensation speed) calculated
from the line speed command,
current winding diameter value,
and gear ratio when dancer
feedback speed control is valid
—
Monitor item
Unit
Pr.52,
Pr.774
to
Pr.776,
Pr.992
RS-485
communication
dedicated
monitor
(hexadecimal)
MODBUS
RTU real time
monitor
Negative
indication
(-)
∗1
Description
Refer
to
page
Summary of Contents for A800 Plus Series