Parameter list (by parameter number)
30
∗1
Differs according to the capacity.
• 6%: FR-A820-00046(0.4K), 00077(0.75K), FR-A840-00023(0.4K), 00038(0.75K)
• 4%: FR-A820-00105(1.5K) to 00250(3.7K), FR-A840-00052(1.5K) to 00126(3.7K)
• 3%: FR-A820-00340(5.5K), 00490(7.5K), FR-A840-00170(5.5K), 00250(7.5K)
• 2%: FR-A820-00630(11K) to 03160(55K), FR-A840-00310(11K) to 01800(55K)
• 1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K) or higher
∗2
The setting range or initial value for the FR-A820-03160(55K) or lower and FR-A840-01800(55K) or lower.
∗3
The setting range or initial value for the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher.
∗4
The initial value for the FR-A820-00490(7.5K) or lower and FR-A840-00250(7.5K) or lower.
∗5
The initial value for the FR-A820-00630(11K) or higher and FR-A840-00310(11K) and higher.
∗6
Differs according to the capacity.
• 4%: FR-A820-00490(7.5K) or lower, FR-A840-00250(7.5K) or lower
• 2%: FR-A820-00630(11K) to 03160(55K), FR-A840-00310(11K) to 01800(55K)
• 1%: FR-A820-03800(75K) or higher, FR-A840-02160(75K)or higher
∗7
The value for the 200 V class.
∗8
The value for the 400 V class.
∗9
The setting is available only when a plug-in option that supports Vector control is installed. For details of the Vector control compatible options
supporting the parameter, refer to the Instruction Manual (Detailed) of the FR-A800 inverter or the Instruction Manual of the Vector control
compatible option.
∗10
The parameter number in parentheses is that used (displayed) on the LCD operation panel and the parameter unit.
∗11
The increment varies depending on the
Pr.358
setting.
∗12
The increment varies depending on the
Pr.1262
setting.
∗13
The setting varies with the
Pr.1401
setting.
∗14
The initial value is for standard models.
∗15
The initial value is for separated converter types.
∗16
The setting is available only when the FR-A8AZ is installed.
∗17
For the details, refer to the Instruction Manual (Detailed) of the FR-A800 inverter in the enclosed CD-ROM.
∗18
For the details, refer to the Instruction Manual of the FR-A8AL.
1428
R559
Mechanical loss setting
frequency 5
0 to 400 Hz, 9999
0.01 Hz
9999
1429
R560
Mechanical loss 5
900 to 1100%
0.1%
1000%
1480
H520
Load characteristics
measurement mode
0, 1 (2 to 5, 81 to 85)
1
0
1481
H521
Load characteristics load
reference 1
0 to 400%, 8888, 9999
0.1%
9999
1482
H522
Load characteristics load
reference 2
0 to 400%, 8888, 9999
0.1%
9999
1483
H523
Load characteristics load
reference 3
0 to 400%, 8888, 9999
0.1%
9999
1484
H524
Load characteristics load
reference 4
0 to 400%, 8888, 9999
0.1%
9999
1485
H525
Load characteristics load
reference 5
0 to 400%, 8888, 9999
0.1%
9999
1486
H526
Load characteristics maximum
frequency
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
1487
H527
Load characteristics minimum
frequency
0 to 590 Hz
0.01 Hz
6 Hz
1488
H531
Upper limit warning detection
width
0 to 400%, 9999
0.1%
20%
1489
H532
Lower limit warning detection
width
0 to 400%, 9999
0.1%
20%
1490
H533
Upper limit fault detection width
0 to 400%, 9999
0.1%
9999
1491
H534
Lower limit fault detection width
0 to 400%, 9999
0.1%
9999
1492
H535
Load status detection signal
delay time / load reference
measurement waiting time
0 to 60 s
0.1s
1s
1499
E415
Parameter for manufacturer setting. Do not set.
Pr.CLR
Parameter clear
(0, )1
1
0
ALL.CL
All parameter clear
(0, )1
1
0
Err.CL
Fault history clear
(0, )1
1
0
Pr.CPY
Parameter copy
(0, )1 to 3
1
0
Pr.CHG
Initial value change list
─
─
─
AUTO
Automatic parameter setting
─
─
─
Pr.Md
Group parameter setting
(0, )1, 2
1
0
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value Refer
to
page
Customer
setting
FM
CA
Summary of Contents for A800 Plus Series
Page 240: ...239 MEMO ...