Parameter list (by parameter number)
11
2
23
H610
Stall prevention operation level
compensation factor at double
speed
0 to 200%, 9999
0.1%
9999
─
24
to
27
D304
to
D307
Multi-speed setting (4 speed to 7
speed)
0 to 590 Hz, 9999
0.01 Hz
9999
─
28
D300
Multi-speed input compensation
selection
0, 1
1
0
─
29
F100
Acceleration/deceleration
pattern selection
0 to 6
1
0
─
30
E300
Regenerative function selection
0 to 2, 10, 11, 20, 21,
100 to 102, 110, 111, 120,
121
1
0
─
31
H420
Frequency jump 1A
0 to 590 Hz, 9999
0.01 Hz
9999
─
32
H421
Frequency jump 1B
9999
─
33
H422
Frequency jump 2A
9999
─
34
H423
Frequency jump 2B
9999
─
35
H424
Frequency jump 3A
9999
─
36
H425
Frequency jump 3B
9999
─
37
M000
Speed display
0, 1 to 9998
1
0
─
41
M441
Up-to-frequency sensitivity
0 to 100%
0.1%
10%
─
42
M442
Output frequency detection
0 to 590 Hz
0.01 Hz
6 Hz
─
43
M443
Output frequency detection for
reverse rotation
0 to 590 Hz, 9999
0.01 Hz
9999
─
44
F020
Second acceleration/
deceleration time
0 to 3600 s
0.1 s
5 s
─
45
F021
Second deceleration time
0 to 3600 s, 9999
0.1 s
9999
─
46
G010
Second torque boost
0 to 30%, 9999
0.1%
9999
─
47
G011
Second V/F (base frequency)
0 to 590 Hz, 9999
0.01 Hz
9999
─
48
H600
Second stall prevention
operation level
0 to 400%
0.1%
150%
─
49
H601
Second stall prevention
operation frequency
0 to 590 Hz, 9999
0.01 Hz
0 Hz
─
50
M444
Second output frequency
detection
0 to 590 Hz
0.01 Hz
30 Hz
─
51
H010
Second electronic thermal O/L
relay
0 to 500 A, 9999
9999
─
0 to 3600 A, 9999
52
M100
Operation panel main monitor
selection
0, 5 to 14, 17 to 20,
22 to 36, 38, 40 to 46,
50 to 57, 61 to 64, 67,
71 to 74, 81 to 93, 97, 98,
100
1
0
54
M300
FM/CA terminal function
selection
1 to 3, 5 to 14, 17 to 19,
21, 22, 24, 26 to 28, 30,
32 to 34, 36, 46, 50, 61,
62, 70, 81, 82, 87 to 90,
92, 93, 97, 98
1
1
55
M040
Frequency monitoring reference
0 to 590 Hz
0.01 Hz
60 Hz
50 Hz
─
56
M041
Current monitoring reference
0 to 500 A
Inverter rated
current
─
57
A702
Restart coasting time
0, 0.1 to 30 s, 9999
0.1 s
9999
─
58
A703
Restart cushion time
0 to 60 s
0.1 s
1 s
─
60
G030
Energy saving control selection
0, 4, 9
1
0
─
65
H300
Retry selection
0 to 5
1
0
─
66
H611
Stall prevention operation
reduction starting frequency
0 to 590 Hz
0.01 Hz
60 Hz 50 Hz
─
67
H301
Number of retries at fault
occurrence
0 to 10, 101 to 110
1
0
─
68
H302
Retry waiting time
0.1 to 600 s
0.1 s
1 s
─
69
H303
Retry count display erase
0
1
0
─
70
G107
Special regenerative brake duty
0 to 100%
0.1%
0%
─
71
C100
Applied motor
0, 1, 3 to 6, 13 to 16, 20,
23, 24, 30, 33, 34, 40, 43,
44, 50, 53, 54, 70, 73, 74
1
0
─
72
E600
PWM frequency selection
1
2
─
0 to 6, 25
Pr.
Pr.
group
Name
Setting range
Minimum
setting
increments
Initial value Refer
to
page
Customer
setting
FM
CA
Summary of Contents for A800 Plus Series