AIR CONDITIONER 
OUTDOOR UNIT

INSTALLATION MANUAL

INSTALLATIONSANLEITUNG

MANUEL D'INSTALLATION

MANUAL DE INSTALACIÓN

MANUALE D'INSTALLAZIONE

ΕΓΧΕΙΡΙΔΙΟ

 

ΕΓΚΑΤΑΣΤΑΣΗΣ

MANUAL DE INSTALAÇÃO

РУКОВОДСТВО

 

ПО

 

УСТАНОВКЕ

MONTAJ KILAVUZU

PART NO. 9379342070-02

For authorized personnel only.

Nur für autorisiertes Personal.

Pour le personnel agréé uniquement.

Solo para personal autorizado.

Ad uso esclusivo del personale autorizzato.

Για

 

εξουσιοδοτημένο

 

προσωπικό

 

σέρβις

.

Apenas para técnicos autorizados.

Для

 

уполномоченного

 

персонала

.

Yetkili servis personeli içindir.

9379342070-02_IM.indb   1

9379342070-02_IM.indb   1

2011-12-21   11:13:04

2011-12-21   11:13:04

Summary of Contents for aoyg18lac2

Page 1: ...AZIONE ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ MANUAL DE INSTALAÇÃO РУКОВОДСТВО ПО УСТАНОВКЕ MONTAJ KILAVUZU PART NO 9379342070 02 For authorized personnel only Nur für autorisiertes Personal Pour le personnel agréé uniquement Solo para personal autorizado Ad uso esclusivo del personale autorizzato Για εξουσιοδοτημένο προσωπικό σέρβις Apenas para técnicos autorizados Для уполномоченного персонала Yetkili servis p...

Page 2: ...ibly result in personal harm to the user or damage to property Read carefully all security information before use or install the air conditioner Do not attempt to install the air conditioner or a part of the air conditioner by yourself This unit must be installed by qualified personnel with a capacity certificate for handling refrigerant fluids Refer to regulation and laws in use on installation p...

Page 3: ...shape Q ty Description Installation Manual 1 This manual Drain pipe 1 For outdoor unit drain piping work Heat Cool model Reverse cycle only Adapter assy 9 52 mm 12 7 mm 1 For use when connecting model 14 to outdoor port A or B 18 type only System configuration 2 4 Layout example for the indoor units and outdoor unit OUTDOOR UNIT 18 TYPE H1 H2 H1 a b Outdoor unit Indoor unit Unit B 7 14 Connection ...

Page 4: ...t and fall off of the balcony CAUTION Do not install the outdoor unit in the following areas Area with high salt content such as at the seaside It will deteriorate metal parts causing the parts to fail or the unit to leak water Area filled with mineral oil or containing a large amount of splashed oil or steam such as a kitchen It will deteriorate plastic parts causing the parts to fail or the unit...

Page 5: ...er do not install the unit with it tilted towards the side containing the compressor When installing the outdoor unit where it may exposed to strong wind fasten it securely Decide the mounting position with the customer as follows 1 Install the outdoor unit in a location which can withstand the weight of the unit and vibration and which can install horizontally 2 Provide the indicated space to ens...

Page 6: ...to the necessary length with a pipe cutter 1 Hold the pipe downward so that the cuttings will not enter the pipe and remove any 2 burrs Insert the flare nut always use the flare nut attached to the indoor and outdoor units 3 respectively onto the pipe and perform the flare processing with a flare tool Leakage of refrigerant may result if other flare nuts are used Protect the pipes by pinching them...

Page 7: ... condenser may overheat Before servicing the unit turn the power supply switch OFF Then do not touch electric parts for 5 minutes due to the risk of electric shock Make sure to perform grounding work Improper grounding work can cause electric shocks CAUTION The primary power supply capacity is for the air conditioner itself and does not include the concurrent use of other devices Do not use crosso...

Page 8: ...acuum pump gauge manifold and charge hose for R410A exclusively Using the same vacuum for different refrigerants may damage the vacuum pump or the unit After connecting the piping check the joints for gas leakage with gas leak detector or soapy water CHECKING GAS LEAKAGE AND PURGING AIR 6 1 1 Gas leak checks are performed using either vacuum or nitrogen gas so select the proper one depending on th...

Page 9: ...aker in accordance with the related laws and regulations and electric company standards CAUTION When the voltage is low and the air conditioner is difficult to start contact the power company the voltage raised TEST RUN 8 The test run method may be different for each indoor unit that is connected Refer to the installation Manual included with each indoor unit CAUTION Always turn on the power 12 ho...