Page 1: ...VDSL2 Converter DCE 5201V BM 5204V BM User s Manual ...

Page 2: ......

Page 3: ...terference in which case the user will be required to correct the interference at his own expense CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures WEEE Warning To avoid the potential effects on the environment and human health as a result of the presence of hazardous substa...

Page 4: ...V BM 14 2 2 The Rear Panel 16 2 2 1 MODE DIP Switch 16 2 2 2 DC power jack 18 3 Installing and Using VDSL Converter 19 3 1 Install the Ethernet Over VDSL2 Converter 19 3 1 1 LAN to LAN connection 20 3 1 2 Connect to Multi Port Master 21 3 2 Connecting DCE 520XV BM 22 3 2 1 Connecting Standalone PC 22 3 2 2 Connecting Multiple PCs to an Ethernet LAN 23 3 3 Chassis Installation and Rack Mounting 520...

Page 5: ...etworking technologies Ethernet and VDSL2 Very high data rate Digital Subscriber Line 2 This technology offers the absolute fastest possible data transmission speeds over existing copper telephone lines without the need for rewiring The 5201V BM 5204V BM 520XV BM Ethernet over VDSL2 Converter Bridge has switching architecture with RJ 45 10 100Mbps Ethernet port and one symmetric Ethernet over VDSL...

Page 6: ... connection are listed as following 10Base T Category 3 4 or 5 UTP 100Base TX Category 5 UTP Ethernet over VDSL Twisted pair telephone wires The two drawings listed below are typical application for the Ethernet over VDSL2 Converter Note Slave device CPE must connect to Master device CO through the telephone wire Slave cannot connect to Slave and Master cannot connect to Master To define the 520XV...

Page 7: ...Telephone wire Up to 1 4km VDSL2 Telephone wire Ethernet over VDSL2 and Telephone Network Main office PBX Telco CO wire closet LAN1 LAN2 DCE 5204V BM CO DCE 5204V BM CPE Up to 1 4km VDSL2 Telephone wire Ethernet over VDSL2 and Telephone Network Main office PBX Telco CO wire closet 1 1 DCE 5201V BM CO DCE 5201V BM CPE Splitter Splitter ...

Page 8: ...port CO Internet Telephone wire LAN1 DCE 5204V BM CPE DCE 5204V BM CPE UP to 1 4km LAN2 Router LAN1 Ethernet over VDSL2 and Telephone Network Main office PBX Telco CO wire closet VDSL2 Switch Multi port CO QWHUQHW Telephone wire 5201V BM CPE 5201V BM CPE Splitter Splitter Ethernet Telephone Network Main office PBX Telco CO wire closet Telephone wire VDSL2 VDSL2 VDSL2 VDSL2 VDSL2 VDSL2 VDSL2 ...

Page 9: ...3u and IEEE 802 3x standards DMT Discrete Multi Tone line coding Half duplex Back pressure and IEEE 802 3x Full Duplex Pause frame flow control Built in POTS splitter to share voice and data 5204V BM only Voice and data communication can be shared on the existing telephone wire simultaneously Hardware IGMP Snooping for Multimedia service 5204V BM only Support up to 1536 bytes packet size 802 1Q VL...

Page 10: ...de Encoding VDSL DMT ITU T G 993 1 VDSL ITU T G 997 1 ITU T G 993 2 VDSL2 Profile 17a 30a Support LED Indicators One Power One Power 3 for RJ 11 VDSL2 3 for RJ 11 VDSL2 2 for per RJ 45 10 100Base TX port 1 for per RJ 45 10 100Base TX port Cabling Ethernet 10Base T 2 pair UTP Cat 3 4 5 up to 100m 328ft 100Base TX 2 pair UTP Cat 5 up to 100m 328ft VDSL Twisted pair telephone wires AWG24 or better up...

Page 11: ...g Scheme Store and Forward Address Table 1K entries 2K entries Flow Control Back pressure for half duplex IEEE 802 3x Pause Frame for full duplex Switch fabric 0 2Gbps 0 8Gbps Throughput packet per second 0 14Mpps 0 59Mpps Network cables 10 100Base TX 2 Pair UTP Cat 3 4 5 100meters max EIA TIA 568 100 ohm STP 100meters max Standard Conformance Regulation Compliance FCC Part 15 Class A CE Standards...

Page 12: ...ning speed 10Mbps 100Mbps in the same converter bridge and automatically distinguish the speed of incoming connection This section describes the hardware features of the Ethernet over VDSL2 Converter Bridge For easier control of the converter Bridge familiarize yourself with its display indicators and ports Front panel illustrations in this chapter display the unit LED indicators Before connecting...

Page 13: ...ights to indicate that the VDSL Converter has power Off Indicate that the VDSL Converter has no power n VDSL LED Color Function VDSL Green Lit Indicate that the VDSL link is established Fast Blink Indicate that the VDSL link is at training status about 10 seconds Slow Blink Indicate that the VDSL link is at idle status CO Green Lit Indicate the VDSL Converter is running at CO mode CPE Green Lit In...

Page 14: ... is link down 100 Green Lit Indicate that the port is operating at 100Mbps Off Indicate that the port is link down or 10Mbps 2 1 2 LED indicators for DCE 5204V BM The rich diagnostic LEDs on the front panel can provide the operating status of individual port and whole system n System LED Color Function PWR Green Lit Lights to indicate that the VDSL Bridge has power Off Indicate that the VDSL Bridg...

Page 15: ...t the VDSL link is at idle status CO Green Lit Indicate the VDSL Bridge is running at CO mode CPE Green Lit Indicate the VDSL Bridge is running at CPE mode n 10 100Base TX Port LED Color Function LNK ACT Green Lit Indicate that the port is link up at 10 100Mbps Blink Indicate that the VDSL Bridge is actively sending or receiving data over that port Off Indicate that the port is link down ...

Page 16: ...ver VDSL2 Converter provides 4 selective transmission modes By switching the transmission modes you can obtain a best transmission mode to suit with phone line quality or distance of connectivity The following is the summary table of transmission setting bandwidth and distance extensibility tested for AWG 24 0 5mm twisted pair without noise and cross talk DIP 1 DIP 2 DIP 3 DIP 4 Mode Channel Profi...

Page 17: ...unction n DIP 2 Channel Fast and Interleave mode Fast mode guarantees a minimum end to end latency less than 1 ms Interleaved mode provides impulse noises protection for any impulse noise with a duration less than 250 us Interleaved mode has a maximum end to end latency of 10m sec n DIP 3 Profile 17A 30A User has the ability to select profile When 30a is selected that provides better downstream up...

Page 18: ...e bundled AC adapter Should you have the issue to make the power connection please contact your local sales representative Note 1 The device is a power required device it means it will not work till it is powered If your networks should active all the time please consider using UPS Uninterrupted Power Supply for your device It will prevent you from network data loss or network downtime 2 In some a...

Page 19: ...ice to Slave device and allows data and voice work on the same telephone lines DCE 5201V BM provides one RJ 11 connector for VDSL port and the port can build VDSL2 connection easily For voice device connection the additional splitter from 5201V BM package is an idea choice DCE 5204V BM provides two RJ 11connectors for VDSL port One for voice device connection like telephone and the other one for n...

Page 20: ...e but one Ethernet over VDSL2 Converters Bridge must be Master CO mode and the other one is Slave CPE mode Telephone wire 100Base TX UTP VDSL2 VDSL2 Phone VDSL2 5201V BM CO 5201V BM CPE Internet PSTN Up to 1 4km Telephone wire Router Switch PBX Figure 3 1 5201V BM LAN to LAN connection Up to 1 4km VDSL2 Telephone wire Telephone wire 100Base TX UTP VDSL2 VDSL2 Internet PSTN Router VDSL2 CO Bridge V...

Page 21: ...o the Multi port Master through the telephone lines When deciding where to put the converter then you must ensure It is accessible and cables can be connected easily Cabling is away from sources of electrical noise such as radios transmitters and power lines and fluorescent lighting fixtures Water or moisture can not enter the Converters Bridge Air flow around the unit and through the vents in the...

Page 22: ... Line port of splitter from 5201V BM package 5 Connect VDSL line from another VDSL device to DSL port of the splitter that connects to 5201V BM VDSL port 6 LNK LED will from blinking to illuminate 7 Connect telephone to the PHONE port of the splitter that connects to 5201V BM VDSL port 8 Connect 5201V BM Ethernet port to PC Network Interface Card NIC via regular Cat 5 cables Telephone wire 100Base...

Page 23: ...e and make a connection between 5201V BM and Line port of splitter from 5201V BM package 5 Connect VDSL line from another VDSL device to DSL port of the splitter that connects to 5201V BM VDSL port 6 Connect VDSL line from another VDSL device to VDSL port of the 5204V BM 7 LNK LED will illuminate 8 Connect telephone to the PHONE port 9 5204V BM Connect Ethernet port to Ethernet Switch or Broad ban...

Page 24: ...p PC Telephone wire 100Base TX UTP 5204V BM Phone RJ 11 Phone Jack RJ 11 Phone Wire IP Cam IP TV Wireless Laptop PC 1 2 3 4 RJ 11 Phone Wire Telephone wire 100Base TX UTP Figure 3 4 Connecting Multiple PCs to an Ethernet LAN Note Please refer to your Ethernet device User s Manual for the device s set up information 5201V BM ...

Page 25: ...n available slot Step 3 Attach a rack mount bracket to each side of the Converter Chassis with supplied screws attached to the package Step 4 After the brackets are attached to the Converter Chassis use suitable screws to securely attach the brackets to the rack Step 5 Connect one end of the power cable to the 10 inch or 19 inch Converter Chassis Step 6 Connect the power plug of the power cable to...

Page 26: ... the issue to make the power connection please contact your local sales representative Please keep the AC DC adapter as spare parts when 5201V BM is installed to a Media Chassis 2 5mm DC Receptacle 2 5mm 5V for each slot DC receptacle is 2 5mm wide that conforms to and matches the VDSL2 Converter 2 5mm DC jack s central post Do not install any improper unit model of the Ethernet Over VDSL2 Convert...

Page 27: ...SYMPTOM TP LED does not light after cable is connected to the port CHECKPOINT 1 Verify you are using the Cat 5 or better cable with RJ 45 connector to connect to the port 2 If your device like LAN card supports to Auto Negotiation please try to manual set at a fixed speed of your device to solve this issue 3 The Converter Bridge and the connected device s power are on or not 4 The port s cable is ...

Page 28: ... upgrade exiting xDSL infrastructure Q3 What is the best distance for 520XV BM A3 In order to guarantee the stability and better quality of network so we would suggest the distance in 1 4 kilometer is the best for 520XV BM Q4 What is the best date rate for 520XV BM A4 We provide the data rate of the 520XV BM is up to 100Mbps 100Mbps downstream upstream in 200 meters Q5 compatible with 520XV BM A5 ...

Page 29: ...identify and subsequently isolate and eliminate the source of noise Generally speaking the higher SNR value gets better line quality but lower performance Q7 What is profile and what s the benefit A7 VDSL2 defines multiple band plans and configuration modes profiles to allow asymmetric and symmetric services in the same binder by designated frequency bands for the transmission of upstream and down...

Page 30: ...This page is intentionally left blank ...