![Manitowoc 140.5.204 Operation Manual Download Page 572](http://html.mh-extra.com/html/manitowoc/140-5-204/140-5-204_operation-manual_701123572.webp)
It is difficult to screw in the locking bolt using the emergency
release screw.
1.
Stop screwing in the locking bolt.
2.
Pull the locking bolt out again.
3.
Check the position of the locking bolt. Readjust the telescopic
thruster. Move the locking bolt into the position for emer-
gency release.
7.20.2.7.6
Pushing back a telescopic thruster which has been released in an emergency
1
Area for positioning using the auxiliary vehicle
Difficulty screwing in the locking
bolt using the emergency release
screw
Operation
27.04.2020
140.5.204 Telescopic crane
572