The ideal position for releasing the locking bolt in an emergency is
reached when the locking bolt is located centrally in the access
opening. Distance A must be reached as a minimum.
Data
Value Unit
A
30 mm
A
1.2 in
Requirement:
The hoisting slings are attached to the telescopic thruster to be
unlocked.
1.
Use the auxiliary vehicle and hoisting slings to pull out the
telescopic thruster until the locking bolt in the access opening
has reached the emergency release position.
2.
Use a tool such as a wooden beam to check that the locking
bolt can move freely.