214657
119
Revision A
Figure 4.56: Case IH Combine Display
4.
Locate HEADER SENSORS and HEADER
PRESSURE FLOAT fields. They will be located on
either HEAD 1 or HEAD 2 tab.
5.
Select ENABLE (A) in HEADER SENSORS field.
6.
Select NO (B) in HEADER PRESSURE FLOAT field.
Figure 4.57: Case IH Combine Display
7.
Engage separator, header, and press preset 1 or 2.
8.
Ensure AUTO HEIGHT icon (A) appears on monitor
and is displayed at location (B) as shown. When header
is set for cutting on ground, this verifies that the
combine is using the potentiometers on the header
correctly to sense ground pressure.
NOTE:
AUTO HEIGHT field (B) may appear on any of RUN
tabs and not necessarily on RUN 1 tab.
Figure 4.58: Case IH Combine Display
9.
Select CALIBRATION on combine display, and press
right arrow navigation key to enter information box.
10. Select HEADER (A), and press ENTER. The
CALIBRATION dialog box opens.
NOTE:
You can use up and down navigation keys to move
between options.
Summary of Contents for PW8
Page 2: ...PW8 Pick Up Header Published May 2018...
Page 3: ...Declaration of Conformity Figure 1 EC Declaration of Conformity 214657 i Revision A...
Page 4: ...Figure 2 EC Declaration of Conformity 214657 ii Revision A...
Page 40: ......
Page 147: ...214657 133 Revision A AHHC SYSTEM...
Page 176: ......
Page 276: ......
Page 282: ......
Page 286: ......