214657
103
Revision A
Figure 4.17: Left Height Sensor
4.
Locate left height sensor (A).
NOTE:
Sensor and connector may not be exactly as shown.
5.
With connector plugged into sensor, measure voltage
between orange signal wire (B) in middle position on
connector, and the brown ground wire (C) at one side of
connector. This is the maximum voltage for the left
sensor.
Figure 4.18: Right Access Panel
6.
Locate access panel (A) on inside of right end frame.