214657
109
Revision A
Figure 4.31: Case IH Combine Display
3.
Select SETTINGS (A). The SETTINGS page opens.
4.
From the GROUP menu (B), select HEADER.
Figure 4.32: Case IH Combine Display
5.
From the PARAMETER menu, select LEFT HEIGHT/
TILT SENSOR (A).
Figure 4.33: Case IH Combine Display
6.
The SETTINGS page updates to display the voltage in
the VALUE/STATUS field (A). Lower the feeder house
fully, and then raise it 305 mm (12 in.) off the ground to
view the full range of voltage readings.
7.
If sensor voltage is not within low and high limits shown
in
4.1.3 Height Sensor Output Voltage Range
Combine Requirements, page 102
, or if range between
low and high limits is insufficient, you need to make
adjustments. For instructions, refer to
Height Sensor Voltage Range (Left Side), page 105
and
Adjusting Header Height Sensor Voltage Range (Right
Side), page 105