214657
125
Revision A
Turning Off Accumulator (John Deere 60 Series)
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Figure 4.66: John Deere Combine Display
1.
Press DIAGNOSTIC button (A) on monitor. DIA
appears on the monitor.
2.
Press UP button (B) until EO1 appears on monitor, and
press ENTER (D). This is header adjustment.
3.
Press UP (B) or DOWN (C) button until 132 is displayed
on top portion of monitor. This is reading for
accumulator.
4.
Press ENTER (D) to select 132 as accumulator reading
(this will allow you to change display to a three-digit
number so it has a 0 in it, for example, x0x).
5.
Press UP (B) or DOWN (C) button until desired number
is displayed, and press CAL (E) button.
6.
Press ENTER (D) to save changes. The accumulator is
now deactivated.