214657
127
Revision A
Setting Sensitivity of Auto Header Height Control (John Deere 60 Series)
This is also known as dead band adjustment.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Figure 4.69: John Deere Combine Display
1.
Press DIAGNOSTIC button (A) on monitor. DIA
appears on the monitor.
2.
Press UP button (B) until EO1 appears on monitor, and
press ENTER (D). This is header adjustment.
3.
Press UP (B) or DOWN (C) button until 112 is displayed
on monitor. This is your sensitivity setting.
NOTE:
The lower the reading, the higher the sensitivity. Ideal
operating range is typically between 50 and 80.
4.
Press ENTER (D) to select 112 as sensitivity setting
(this will allow you to change first digit of number
sequence).
5.
Press UP (B) or DOWN (C) until desired number is
displayed, then press CAL (E) button. This will bring
you to second digit. Repeat this procedure until desired
setting is achieved.
6.
Press ENTER (D) to save changes.
NOTE:
The numbers depicted on displays in these illustrations
are for reference purposes only; they are not intended
to represent specific settings for your equipment.
Adjusting Threshold for Drop Rate Valve (John Deere 60 Series)
This procedure explains how to adjust point at which restrictor valve opens allowing full flow to lift cylinders.
NOTE:
Changes may have been made to combine controls or display since this document was published. Refer to
combine operator
’
s manual for updates.
Summary of Contents for PW8
Page 2: ...PW8 Pick Up Header Published May 2018...
Page 3: ...Declaration of Conformity Figure 1 EC Declaration of Conformity 214657 i Revision A...
Page 4: ...Figure 2 EC Declaration of Conformity 214657 ii Revision A...
Page 40: ......
Page 147: ...214657 133 Revision A AHHC SYSTEM...
Page 176: ......
Page 276: ......
Page 282: ......
Page 286: ......