4. COOLING SYSTEM
4-6
RADIATOR FAN
Radiator fan removal
Remove the mounting bolts
.
Remove the radiator fan.
Radiator fan test
The radiator fan should turn on when coolant
temperature reaches 82
℃
and should turn off
when the coolant cools down at 80
℃
. It should
turn on when connecting to battery directly by
cables.
Radiator fan installation
For the installation, reverse the removal
procedure.
WATER PUMP HOUSING
It is located on the engine MAG side.
Water pump housing removal
Drain cooling system.
Remove radiator outlet hose from water pump
housing.
Remove screws retaining water pump housing.
1.
Screws
2.
Water pump housing
3.
Sealing ring
Pull water pump housing to remove it.
Water pump housing inspection
Check if gasket is brittle, hard or damage and
replace as necessary.
1.
Gasket
Water pump housing installation
The installation is the opposite of the removal
procedure.
CAUTION: To prevent leaking, take care that
the gasket is exactly in groove when you
reinstall the water pump housing.
Tighten screws of water pump housing in a
crisscross sequence.
WARNING
To avoid potential burns, do not remove
the radiator cap or loosen the cooling drain
plug if the engine is hot.
Summary of Contents for UTV1000-3
Page 10: ......
Page 30: ......
Page 38: ...3 ENGINE 3 8 LUBRICATION SYSTEM COMPONENTS...
Page 47: ...3 ENGINE 3 17 MAGNETO SYSTEM...
Page 75: ...3 ENGINE 3 47 ENGINE DRIVE SHAFT CRANKCASE AND PTO COVER...
Page 76: ...3 ENGINE 3 48 CRANKSHAFT...
Page 77: ...3 ENGINE 3 49...
Page 101: ...3 ENGINE 3 73 GEARBOX...
Page 130: ......
Page 142: ......
Page 152: ...8 SUSPENSION SYSTEM 8 6...
Page 160: ......
Page 170: ......