10. ELECTRICAL SYSTEM
10-
2
CHARGING SYSTEM
Resistance of generator coil
Z
Measure the resistance between
three wires;
Z
If the resistance is not within the
specified value, replace the stator
coil.
Z
Check the generator core whether it
is insulated. Install multimeter
1×10Ω.
Resistance of generator coil: 0.9-1.5Ω
(color: yellow)
Insulation resistance ∞Ω (
yellow -
grounding wire
)
No- load performance of the generator
Z
Start the engine with the speed at
5000r/min.
Z
Measure AC voltage three wires
inside the generator with the
multimeter.
Z
If the voltage drops below a specified value, replace the generator.