Parameter description:
Clock Source:
Select which clock source is used for the GS-2300 series. You can select “Use local Settings” or “Use NTP Server” as the
switchs' time clock source.
Local Time:
Shows the current time of the system.
Time Zone Offset:
Provides the time zone offset relative to UTC/GMT. The offset is given in minutes east of GMT. The valid range is from
-720 to 720 minutes
Daylight Saving:
Daylight saving is adopted in some countries. If set, it will adjust the time according to the starting date and the ending
date by the given amount. For example, you set the day light saving to be 1 hour. When the time passes over the starting
time, the system time will be increased by one hour after one minute. When the time passes over the ending time, the
system time will be decreased one hour after one minute.
The switch supports a configurable day light saving time offset of up to 24 hours. The zero for this parameter means it
need not have to adjust current time, equivalent to in-act daylight saving. If you set daylight saving to be non-zero, you
have to set the starting/ending date as well; otherwise, the daylight saving function will not be activated.
Time Set Offset:
Provide the Daylight saving time set offset. The offset is given in minutes east of GMT. The valid range is from 1 to 1440
minutes. default is 60 min
Daylight Savings Type:
Provide the Daylight savings type selection. You can select “ By Dates” or “Recurring” two type for Daylight saving type.
From:
To configure Daylight saving start date and time, the format is “YYYY-MM-DD HH:MM”.
To:
To configure Daylight saving end date and time, the format is “YYYY-MM-DD HH:MM”.
142
LANCOM GS-2310P/GS-2326(P) User Manual
4 System Configuration