Port Copy:
Select which port frames are copied on. The allowed values are Disabled or a specific port number. The default value is
"Disabled".
Mirror:
Specify the mirror operation of this port. The allowed values are:
Enabled: Frames received on the port are mirrored.
Disabled: Frames received on the port are not mirrored.
The default value is "Disabled".
Logging:
Specify the logging operation of this port. The allowed values are:
Enabled: Frames received on the port are stored in the System Log.
Disabled: Frames received on the port are not logged.
The default value is "Disabled". Please note that the System Log memory size and logging rate is limited.
Shutdown:
Specify the port shut down operation of this port. The allowed values are:
Enabled: If a frame is received on the port, the port will be disabled.
Disabled: Port shut down is disabled.
The default value is "Disabled".
Counter:
Counts the number of frames that match this ACE.
Buttons
Save – Click to save changes.
Reset – Click to undo any changes made locally and revert to previously saved values.
Refresh
Refresh the ACL Port Configuration manually.
Clear
Clear the ACL Port Configuration manually.
3.2.2 Rate Limiters
The section describes how to configure the switch’s ACL Rate Limiter parameters. The Rate Limiter Level from 1 to 16
allows the user to set rate limiter values and units (pps or kbps).
Web Interface
To configure ACL Rate Limiter in the web interface:
1. Click Configuration, ACL, then Rate Limiter
2. Specify the Rate field and the range from 0 to 3276700.
3. Select the unit: pps or kbps.
4. Click Apply to save the settings.
5. If you want to cancel the setting then you need to click the reset button. It will revert to previously saved values.
Figure 3-2.2: The ACL Rate Limiter Configuration