Query Response Interval. The Maximum Response Delay used to calculate the Maximum Response Code inserted into
the periodic General Queries. The allowed range is 0 to 31744 in tenths of seconds; default query response interval is
100 in tenths of seconds (10 seconds).
LLQI (LMQI for IGMP):
Last Listener Query Interval. The Last Listener Query Interval is the Maximum Response Delay used to calculate the
Maximum Response Code inserted into Multicast Address Specific Queries sent in response to Version 1 Multicast Listener
Done messages. It is also the Maximum Response Delay used to calculate the Maximum Response Code inserted into
Multicast Address and Source Specific Query messages. The allowed range is 0 to 31744 in tenths of seconds; default
last listener query interval is 10 in tenths of seconds (1 second).
URI:
Unsolicited Report Interval. The Unsolicited Report Interval is the time between repetitions of a node's initial report of
interest in a multicast address. The allowed range is 0 to 31744 seconds, default unsolicited report interval is 1 second.
Refresh
Refresh the IGMP Group Status manually.
<<, >>
Go to the previous/next page or entry.
Save – Click to save changes.
Reset – Click to undo any changes made locally and revert to previously saved values.
3.6.3 Port Group Filtering
The section describes how to set the Port Group Filtering in the MLD Snooping function.
Web Interface
To configure the MLD Snooping Port Group in the web interface:
1. Click Configuration, MLD Snooping, Port Group Filtering Configuration
2. Click Add new Filtering Group
3. Specify the Filtering Group
4. Click Apply to save the setting
5. If you want to cancel the setting then you need to click the Reset button. It will revert to previously saved values
Figure 3-7.3: The MLD Snooping Port Group Filtering Configuration
54
LANCOM GS-2310P/GS-2326(P) User Manual
3 Configuration