Parameter description:
Activate Alternate Image:
Click to use the alternate image. This button may be disabled depending on system state.
Cancel:
Cancel activating the backup image. Navigates away from this page.
Image:
The flash index name of the firmware image. The name of the primary (preferred) image is image, the alternate image
is named image.bk.
Version:
The version of the firmware image.
Date:
The date where the firmware was produced.
5
In case the active firmware image is the alternate image, only the "Active Image" table is shown. In this case,
the Activate Alternate Image button is also disabled.
If the alternate image is active (due to a corruption of the primary image or manually intervention), uploading
a new firmware image to the device will automatically use the primary image slot and activate it.
The firmware version and date information may be empty for older firmware releases. This does not constitute
an error.
6.3 Save / Restore
This section describes how to save and restore the Switch configuration including reset to Factory Defaults, Save Start,
Save Users, Restore Users for any maintenance needs.
6.3.1 Factory Defaults
This section describes how to reset the switch configuration to factory defaults. Any configuration files or scripts will be
set to factory default values.
5
Restoring factory defaults can also be performed by pushing the reset button for more than 10 seconds.
Web Interface
To reset to Factory Defaults in the web interface:
1. Click "Factory Defaults".
2. Click "Yes".
Figure 6-3.1: The Factory Defaults
198
LANCOM GS-2310P/GS-2326(P) User Manual
6 Maintenance